IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,532

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0251 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,122 $194 Implemented
LE0250 # 04 Y:2007 04 2007 INSTALL OCCUPANCY SENSORS $5,950 $800 Implemented
LE0250 # 05 Y:2007 05 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,181 $300 Implemented
LE0250 # 06 Y:2007 06 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,288 $1,500 Implemented
LE0250 # 07 Y:2007 07 2007 TURN OFF EQUIPMENT WHEN NOT IN USE $1,147 $750 Implemented
LE0250 # 08 Y:2007 08 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,083 $14,479 Implemented
LE0249 # 01 Y:2007 01 2007 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $143,645 $50,000 Implemented
LE0249 # 02 Y:2007 02 2007 REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS $61,899 $515,000 Implemented
LE0248 # 04 Y:2007 04 2007 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,065 $11,000 Implemented
LE0248 # 05 Y:2007 05 2007 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,500 $2,500 Implemented
LE0248 # 06 Y:2007 06 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,990 $400 Implemented
LE0248 # 08 Y:2007 08 2007 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $613 $20 Implemented
LE0248 # 09 Y:2007 09 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,674 $25,073 Implemented
WV0353 # 03 Y:2007 03 2007 REPAIR OR REPLACE STEAM TRAPS $48,101 $4,000 Implemented
WV0353 # 06 Y:2007 06 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,776 $300 Implemented
WV0353 # 07 Y:2007 07 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,148 $19,000 Implemented
WV0353 # 10 Y:2007 10 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,101 $3,500 Implemented
WV0353 # 11 Y:2007 11 2007 DEVELOP A REPAIR/REPLACE POLICY $1,883 $400 Implemented
WV0353 # 13 Y:2007 13 2007 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $887 $200 Implemented
WV0353 # 14 Y:2007 14 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $796 $3,000 Implemented
SU0246 # 01 Y:2007 01 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,554 $0 Implemented
SU0246 # 02 Y:2007 02 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,404 $0 Implemented
SU0246 # 03 Y:2007 03 2007 USE SYNTHETIC LUBRICANT $2,489 $0 Implemented
SU0246 # 05 Y:2007 05 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,989 $42 Implemented
SU0246 # 06 Y:2007 06 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,230 $850 Implemented