Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,631
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0305 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,329 | $4,720 | Implemented |
UM0305 # 07 Y:2006 | 07 | 2006 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,689 | $4,660 | Implemented |
UM0305 # 09 Y:2006 | 09 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,248 | $75 | Implemented |
UD0742 # 02 Y:2006 | 02 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $198,228 | $100,000 | Implemented |
UD0742 # 04 Y:2006 | 04 | 2006 | REDESIGN PROCESS | $174,377 | $0 | Implemented |
UD0742 # 09 Y:2006 | 09 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $55,855 | $10,000 | Implemented |
UD0742 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,660 | $122,500 | Implemented |
UD0742 # 12 Y:2006 | 12 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,230 | $0 | Implemented |
UD0742 # 14 Y:2006 | 14 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $17,949 | $0 | Implemented |
UD0742 # 16 Y:2006 | 16 | 2006 | REDUCE WATER USE WITH COUNTER CURRENT RINSING | $7,083 | $0 | Implemented |
UD0742 # 18 Y:2006 | 18 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,020 | $0 | Implemented |
UD0742 # 19 Y:2006 | 19 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $874 | $867 | Implemented |
UD0743 # 06 Y:2006 | 06 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $25,328 | $0 | Implemented |
UD0743 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,000 | $1,800 | Implemented |
UD0743 # 08 Y:2006 | 08 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $18,000 | $1,750 | Implemented |
UD0743 # 09 Y:2006 | 09 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $17,000 | $0 | Implemented |
UD0743 # 10 Y:2006 | 10 | 2006 | REDUCE EXCESSIVE BOILER BLOWDOWN | $15,000 | $0 | Implemented |
UD0743 # 20 Y:2006 | 20 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,342 | $500 | Implemented |
UD0743 # 21 Y:2006 | 21 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $831 | $0 | Implemented |
UM0301 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $6,754 | $1,971 | Implemented |
UM0301 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,457 | $375 | Implemented |
UM0301 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,325 | $0 | Implemented |
UD0741 # 03 Y:2006 | 03 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $18,067 | $110 | Implemented |
UD0741 # 04 Y:2006 | 04 | 2006 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $16,240 | $0 | Implemented |
UD0741 # 05 Y:2006 | 05 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $9,135 | $2,800 | Implemented |