IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

158,469

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0550 # 01 Y:2023 01 2023 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,435 $22,586 Implemented
AS0550 # 02 Y:2023 02 2023 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,005 $6,140 Implemented
AS0550 # 03 Y:2023 03 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $152 $109 Implemented
AS0551 # 01 Y:2023 01 2023 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $2,434 $2,202 Implemented
AS0551 # 02 Y:2023 02 2023 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,528 $7,174 Implemented
AS0551 # 03 Y:2023 03 2023 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,477 $3,284 Implemented
AS0551 # 04 Y:2023 04 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $784 $3,277 Implemented
AS0551 # 05 Y:2023 05 2023 USE PHOTOCELL CONTROLS $378 $819 Implemented
AS0552 # 01 Y:2023 01 2023 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,561 $2,573 Not Implemented
AS0552 # 02 Y:2023 02 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,547 $1,915 Implemented
AS0552 # 03 Y:2023 03 2023 REDUCE HEAT GAIN BY WINDOW TINTING $1,124 $4,833 Not Implemented
AS0552 # 04 Y:2023 04 2023 KEEP EQUIPMENT CLEAN $874 $25 Not Implemented
AS0552 # 05 Y:2023 05 2023 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $357 $10,234 Implemented
AS0552 # 06 Y:2023 06 2023 SHADE WINDOWS FROM SUMMER SUN $281 $550 Implemented
AS0552 # 07 Y:2023 07 2023 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $150 $505 Not Implemented
SJ0003 # 01 Y:2023 01 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $57,369 $319,999 Implemented
SJ0003 # 02 Y:2023 02 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $103 $218 Implemented
SJ0003 # 03 Y:2023 03 2023 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,596 $5,020 Implemented
SJ0003 # 04 Y:2023 04 2023 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $326 $20 Implemented
SJ0003 # 05 Y:2023 05 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $960 $2,889 Implemented
SU0531 # 01 Y:2023 01 2023 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $6,031 $0 n/a
SU0531 # 02 Y:2023 02 2023 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,557 $0 n/a
SU0531 # 03 Y:2023 03 2023 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,464 $0 n/a
SU0531 # 04 Y:2023 04 2023 DISCONNECT BALLASTS $603 $0 n/a
SU0531 # 05 Y:2023 05 2023 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,436 $70 n/a