IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

158,455

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0022 # 01 Y:1988 01 1988 INSULATE BARE EQUIPMENT $3,075 $6,920 Implemented
AM0022 # 02 Y:1988 02 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,302 $2,700 Implemented
AM0022 # 03 Y:1988 03 1988 MODERATE COOLING TOWER OUTLET TEMPERATURE $945 $550 Not Implemented
AM0022 # 04 Y:1988 04 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $884 $520 Implemented
AM0022 # 05 Y:1988 05 1988 IMPROVE LUBRICATION PRACTICES $476 $0 Not Implemented
AM0022 # 06 Y:1988 06 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $238 $0 Not Implemented
AM0022 # 07 Y:1988 07 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $137 $319 Not Implemented
AM0022 # 08 Y:1988 08 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $59 $192 Not Implemented
AM0023 # 01 Y:1988 01 1988 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,044 $1,000 Implemented
AM0023 # 02 Y:1988 02 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,902 $80 Implemented
AM0023 # 03 Y:1988 03 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $114 $80 Implemented
AM0024 # 01 Y:1988 01 1988 BURN A LESS EXPENSIVE GRADE OF FUEL $1,734 $0 Implemented
AM0024 # 02 Y:1988 02 1988 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,080 $3,440 Not Implemented
AM0024 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $195 $792 Implemented
AM0025 # 01 Y:1988 01 1988 USE DEMAND CONTROLLER OR LOAD SHEDDER $8,582 $15,000 Not Implemented
AM0025 # 02 Y:1988 02 1988 INSULATE BARE EQUIPMENT $913 $1,116 Implemented
AM0025 # 03 Y:1988 03 1988 INSTALL SET-BACK TIMERS $797 $0 Implemented
AM0025 # 04 Y:1988 04 1988 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $422 $0 Implemented
AM0025 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $72 $72 Implemented
AM0025 # 06 Y:1988 06 1988 INSTALL SET-BACK TIMERS $159 $0 Implemented
AM0026 # 01 Y:1988 01 1988 TURN OFF EQUIPMENT WHEN NOT IN USE $867 $2,000 Implemented
AM0026 # 02 Y:1988 02 1988 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $8,053 $1,075 Implemented
AM0026 # 03 Y:1988 03 1988 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $4,962 $10,000 Not Implemented
AM0026 # 04 Y:1988 04 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $851 $300 Implemented
AM0026 # 05 Y:1988 05 1988 TURN OFF EQUIPMENT WHEN NOT IN USE $492 $123 Not Implemented