Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
161,963
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0206 # 03 Y:1984 | 03 | 1984 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $14,224 | $9,000 | Implemented |
GT0206 # 04 Y:1984 | 04 | 1984 | INSULATE BARE EQUIPMENT | $5,168 | $6,540 | Not Implemented |
GT0208 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,150 | $1,550 | Implemented |
GT0208 # 02 Y:1984 | 02 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,482 | $6,948 | Implemented |
GT0208 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,580 | $5,660 | Implemented |
GT0208 # 04 Y:1984 | 04 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,720 | $0 | Implemented |
GT0208 # 05 Y:1984 | 05 | 1984 | REDESIGN PROCESS | $10,210 | $20,000 | Implemented |
GT0208 # 06 Y:1984 | 06 | 1984 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $18,300 | $20,000 | Implemented |
GT0209 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,600 | $500 | Implemented |
GT0209 # 02 Y:1984 | 02 | 1984 | MODIFY DYE BECK | $77,000 | $100,000 | Not Implemented |
GT0209 # 03 Y:1984 | 03 | 1984 | MODIFY DYE BECK | $23,700 | $0 | Not Implemented |
GT0209 # 04 Y:1984 | 04 | 1984 | MODIFY DYE BECK | $7,435 | $60,000 | Not Implemented |
GT0209 # 05 Y:1984 | 05 | 1984 | MODIFY DYE BECK | $7,227 | $15,000 | Not Implemented |
GT0209 # 06 Y:1984 | 06 | 1984 | MODIFY TEXTILE DRYERS | $24,720 | $20,000 | Not Implemented |
GT0209 # 07 Y:1984 | 07 | 1984 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $11,360 | $10,000 | Not Implemented |
GT0209 # 08 Y:1984 | 08 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,672 | $5,000 | Implemented |
GT0209 # 09 Y:1984 | 09 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $17,472 | $40,000 | Not Implemented |
KU0112 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $18,588 | $1,074 | Implemented |
KU0112 # 02 Y:1984 | 02 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,459 | $0 | Not Implemented |
KU0112 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,757 | $12,786 | Not Implemented |
KU0112 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $795 | $200 | Implemented |
KU0112 # 05 Y:1984 | 05 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $398 | $400 | Implemented |
KU0112 # 06 Y:1984 | 06 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,012 | $2,800 | Implemented |
KU0112 # 07 Y:1984 | 07 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,000 | $360 | Not Implemented |
KU0112 # 08 Y:1984 | 08 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $286 | $0 | Implemented |