Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
161,963
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0092 # 04 Y:1983 | 04 | 1983 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,856 | $10,000 | Not Implemented |
OK0092 # 05 Y:1983 | 05 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $2,180 | $1,000 | Not Implemented |
OK0092 # 06 Y:1983 | 06 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $884 | $1,500 | Not Implemented |
OK0092 # 07 Y:1983 | 07 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $516 | $352 | Not Implemented |
OK0093 # 01 Y:1983 | 01 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $470 | $824 | Not Implemented |
OK0093 # 02 Y:1983 | 02 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $752 | $2,405 | Not Implemented |
OK0093 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $233 | $103 | Not Implemented |
OK0094 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $764 | $183 | Not Implemented |
OK0094 # 02 Y:1983 | 02 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19 | $45 | Not Implemented |
OK0094 # 03 Y:1983 | 03 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $988 | $800 | Not Implemented |
OK0094 # 04 Y:1983 | 04 | 1983 | REPAIR AND ELIMINATE STEAM LEAKS | $2,438 | $1,127 | Implemented |
OK0094 # 05 Y:1983 | 05 | 1983 | OPTIMIZE PLANT POWER FACTOR | $728 | $545 | Not Implemented |
OK0094 # 06 Y:1983 | 06 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $263 | $200 | Implemented |
OK0094 # 07 Y:1983 | 07 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $24 | $30 | Not Implemented |
OK0094 # 08 Y:1983 | 08 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $156 | $47 | Implemented |
OK0094 # 09 Y:1983 | 09 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $87 | $51 | Implemented |
OK0094 # 10 Y:1983 | 10 | 1983 | INSTALL / REPAIR INSULATION ON STEAM LINES | $97 | $49 | Not Implemented |
OK0095 # 01 Y:1983 | 01 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $147 | $250 | Not Implemented |
OK0095 # 02 Y:1983 | 02 | 1983 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,400 | $154 | Not Implemented |
OK0095 # 03 Y:1983 | 03 | 1983 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $806 | $1,825 | Not Implemented |
OK0095 # 04 Y:1983 | 04 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $345 | $193 | Not Implemented |
OK0095 # 05 Y:1983 | 05 | 1983 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $196 | $165 | Not Implemented |
OK0095 # 06 Y:1983 | 06 | 1983 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $858 | $169 | Not Implemented |
OK0095 # 07 Y:1983 | 07 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $530 | $428 | Not Implemented |
OK0098 # 01 Y:1983 | 01 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $985 | $100 | Implemented |