Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
92
matching recommendationsSIC | 3533 | Oil And Gas Field Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0191 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,388 | $4,960 | Implemented |
LL0191 # 02 Y:2004 | 02 | 2004 | USE PHOTOCELL CONTROLS | $10,938 | $420 | Implemented |
LL0188 # 01 Y:2004 | 01 | 2004 | ADD AREA LIGHTING SWITCHES | $37,447 | $4,522 | Implemented |
LL0176 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,009 | $1,200 | Implemented |
LL0176 # 06 Y:2003 | 06 | 2003 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,000 | $0 | Implemented |
LL0176 # 01 Y:2003 | 01 | 2003 | INSTALL OCCUPANCY SENSORS | $4,838 | $903 | Implemented |
LL0176 # 04 Y:2003 | 04 | 2003 | USE PHOTOCELL CONTROLS | $590 | $112 | Implemented |
LL0176 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $278 | $80 | Implemented |
LL0164 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $843 | $520 | Implemented |
LL0161 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $641 | $20 | Implemented |
LL0161 # 03 Y:2003 | 03 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,921 | $192 | Implemented |
LL0161 # 02 Y:2003 | 02 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,952 | $2,121 | Implemented |
LL0152 # 01 Y:2003 | 01 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,992 | $825 | Implemented |
LL0152 # 06 Y:2003 | 06 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $8,995 | $12,400 | Implemented |
LL0152 # 03 Y:2003 | 03 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,939 | $3,429 | Implemented |
LL0152 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,007 | $0 | Implemented |
LL0151 # 08 Y:2003 | 08 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $9,556 | $12,425 | Implemented |
LL0151 # 07 Y:2003 | 07 | 2003 | FILTER AND REUSE HYDRAULIC OIL | $40,689 | $8,000 | Implemented |
LL0151 # 06 Y:2003 | 06 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,284 | $180 | Implemented |
LL0151 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES | $3,410 | $1,240 | Implemented |
LL0151 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,605 | $4,350 | Implemented |
LL0149 # 01 Y:2002 | 01 | 2002 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $1,932 | $1,499 | Implemented |
LL0149 # 05 Y:2002 | 05 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,505 | $2,255 | Implemented |
LL0149 # 04 Y:2002 | 04 | 2002 | INSTALL SKYLIGHTS | $1,206 | $1,660 | Implemented |
LL0124 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $537,467 | $121,200 | Implemented |