Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
200
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0209 # 03 Y:1986 | 03 | 1986 | INSTALL AUTOMATIC STACK DAMPER | $19,573 | $13,500 | Not Implemented |
KU0206 # 08 Y:1986 | 08 | 1986 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $474 | $0 | Implemented |
KU0206 # 04 Y:1986 | 04 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,243 | $0 | Not Implemented |
KU0209 # 04 Y:1986 | 04 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $25,756 | $5,000 | Not Implemented |
KU0206 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,289 | $5,696 | Implemented |
KU0203 # 04 Y:1986 | 04 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $5,188 | $1,000 | Implemented |
KU0203 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,598 | $10,800 | Implemented |
KU0203 # 08 Y:1986 | 08 | 1986 | INSTALL AUTOMATIC STACK DAMPER | $303 | $750 | Implemented |
KU0204 # 01 Y:1986 | 01 | 1986 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $50,936 | $300,000 | Not Implemented |
KU0202 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $472 | $0 | Implemented |
KU0203 # 09 Y:1986 | 09 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $285 | $0 | Implemented |
KU0203 # 05 Y:1986 | 05 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,800 | $300 | Implemented |
KU0205 # 07 Y:1986 | 07 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $396 | $0 | Not Implemented |
KU0205 # 05 Y:1986 | 05 | 1986 | INSTALL AUTOMATIC STACK DAMPER | $1,085 | $1,500 | Not Implemented |
KU0203 # 06 Y:1986 | 06 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,080 | $1,500 | Not Implemented |
KU0203 # 07 Y:1986 | 07 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $730 | $117 | Implemented |
KU0204 # 10 Y:1986 | 10 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $126 | $0 | Not Implemented |
KU0203 # 02 Y:1986 | 02 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $190 | $10 | Implemented |
KU0202 # 04 Y:1986 | 04 | 1986 | INSTALL AUTOMATIC STACK DAMPER | $702 | $1,100 | Not Implemented |
KU0202 # 01 Y:1986 | 01 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $17,707 | $200 | Implemented |
KU0202 # 05 Y:1986 | 05 | 1986 | IMPROVE LUBRICATION PRACTICES | $568 | $100 | Implemented |
KU0204 # 08 Y:1986 | 08 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $576 | $50 | Implemented |
KU0202 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,519 | $3,765 | Implemented |
KU0205 # 06 Y:1986 | 06 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $648 | $0 | Implemented |
KU0205 # 04 Y:1986 | 04 | 1986 | IMPROVE LUBRICATION PRACTICES | $1,162 | $615 | Not Implemented |