Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
297
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0388 # 07 Y:2009 | 07 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,366 | $3,122 | Implemented |
WV0388 # 08 Y:2009 | 08 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,801 | $34 | Implemented |
UD0764 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $35,952 | $98,336 | Implemented |
UD0764 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,818 | $49,600 | Implemented |
UD0764 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,675 | $1,275 | Implemented |
UD0764 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $3,230 | $760 | Implemented |
UD0764 # 08 Y:2007 | 08 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,437 | $0 | Implemented |
UD0754 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $135,639 | $80,000 | Implemented |
UD0754 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $74,891 | $305,325 | Implemented |
UD0754 # 04 Y:2007 | 04 | 2007 | MINIMIZE WATER USAGE | $17,430 | $700 | Implemented |
UD0740 # 02 Y:2006 | 02 | 2006 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $107,569 | $256,000 | Implemented |
UD0740 # 03 Y:2006 | 03 | 2006 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $56,879 | $252,100 | Implemented |
UD0740 # 05 Y:2006 | 05 | 2006 | USE PHOTOCELL CONTROLS | $42,737 | $0 | Implemented |
UD0740 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,352 | $2,280 | Implemented |
UD0740 # 09 Y:2006 | 09 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,096 | $0 | Implemented |
UD0740 # 10 Y:2006 | 10 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,805 | $1,500 | Implemented |
UD0740 # 11 Y:2006 | 11 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,326 | $1,700 | Implemented |
UD0740 # 12 Y:2006 | 12 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,280 | $0 | Implemented |
UD0740 # 13 Y:2006 | 13 | 2006 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $223 | $0 | Implemented |
UD0737 # 01 Y:2006 | 01 | 2006 | ELIMINATE/REDUCE AN OPERATION | $448,000 | $-70,000 | Implemented |
UD0737 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,238 | $6,552 | Implemented |
UD0725 # 03 Y:2005 | 03 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,863 | $28,350 | Implemented |
UD0725 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,772 | $18,444 | Implemented |
UD0725 # 05 Y:2005 | 05 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,315 | $1,320 | Implemented |
UD0725 # 08 Y:2005 | 08 | 2005 | INSULATE BARE EQUIPMENT | $1,968 | $0 | Implemented |