Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

326

matching recommendations
Reset
SIC 228 Yarn And Thread Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0136 # 04 Y:1996 04 1996 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $47,059 $145,000 Implemented
HO0136 # 05 Y:1996 05 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $5,736 $6,500 Implemented
GT0589 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,480 $123,250 Implemented
GT0589 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $47,750 $83,090 Implemented
GT0589 # 03 Y:1996 03 1996 USE SYNTHETIC LUBRICANT $6,670 $0 Implemented
GT0589 # 04 Y:1996 04 1996 DISCONNECT BALLASTS $200 $210 Implemented
NC0088 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $565 $240 Implemented
NC0088 # 07 Y:1996 07 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,762 $1,717 Implemented
NC0088 # 08 Y:1996 08 1996 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $5,334 $3,168 Implemented
NC0088 # 09 Y:1996 09 1996 CONTRACT A WOOD PALLET RECYCLING COMPANY $263 $100 Implemented
NC0059 # 01 Y:1995 01 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,340 $0 Implemented
NC0059 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $802 $450 Implemented
NC0059 # 04 Y:1995 04 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $14,062 $1,540 Implemented
NC0059 # 07 Y:1995 07 1995 RECOVER AND REUSE WASTE MATERIAL $40,000 $0 Implemented
GT0529 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,460 $34,270 Implemented
GT0529 # 06 Y:1994 06 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $22,900 $4,000 Implemented
GT0521 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,060 $21,660 Implemented
GT0521 # 02 Y:1994 02 1994 DISCONNECT BALLASTS $360 $640 Implemented
GT0521 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,620 $17,130 Implemented
GT0521 # 06 Y:1994 06 1994 USE MINIMUM STEAM OPERATING PRESSURE $200 $0 Implemented
GT0521 # 08 Y:1994 08 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $890 $900 Implemented
GT0521 # 09 Y:1994 09 1994 REPAIR AND ELIMINATE STEAM LEAKS $11,670 $700 Implemented
GT0515 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $680 $500 Implemented
GT0515 # 08 Y:1993 08 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $41,820 $80,090 Implemented
ME0112 # 01 Y:1993 01 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $745 $100 Implemented