Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
484
matching recommendationsSIC | 2431 | Millwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0222 # 06 Y:2001 | 06 | 2001 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $3,000 | $1,000 | Implemented |
WI0402 # 03 Y:2001 | 03 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,905 | $8,955 | Implemented |
WI0402 # 10 Y:2001 | 10 | 2001 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,181 | $0 | Implemented |
IA0270 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,344 | $160 | Implemented |
IA0270 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $949 | $120 | Implemented |
IA0270 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $651 | $1,176 | Implemented |
IA0265 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,585 | $989 | Implemented |
IA0265 # 04 Y:2001 | 04 | 2001 | AVOID CONTAMINATION OF END PIECES AND REUSE AS FEED STOCK | $18,000 | $22,100 | Implemented |
IA0265 # 06 Y:2001 | 06 | 2001 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $11,603 | $1,088 | Implemented |
AM0396 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,830 | $100 | Implemented |
AM0396 # 03 Y:2001 | 03 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,240 | $0 | Implemented |
AM0396 # 04 Y:2001 | 04 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,980 | $3,960 | Implemented |
AM0396 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,460 | $500 | Implemented |
AM0390 # 02 Y:2001 | 02 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $51,050 | $150,000 | Implemented |
AM0390 # 06 Y:2001 | 06 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $1,600 | $0 | Implemented |
AM0390 # 07 Y:2001 | 07 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,545 | $3,090 | Implemented |
AM0390 # 09 Y:2001 | 09 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,100 | $200 | Implemented |
AM0390 # 10 Y:2001 | 10 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,080 | $50 | Implemented |
AM0390 # 12 Y:2001 | 12 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $680 | $0 | Implemented |
OK0608 # 01 Y:2000 | 01 | 2000 | INSTALL SET-BACK TIMERS | $851 | $263 | Implemented |
OK0608 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,589 | $5,995 | Implemented |
OK0608 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,670 | $1,060 | Implemented |
OK0608 # 05 Y:2000 | 05 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $14,152 | $0 | Implemented |
UF0265 # 01 Y:2000 | 01 | 2000 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $367 | $1,196 | Implemented |
UF0265 # 02 Y:2000 | 02 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,497 | $50 | Implemented |