Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
868
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0257 # 06 Y:2003 | 06 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,738 | $220 | Implemented |
WV0257 # 09 Y:2003 | 09 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $37,016 | $1,000 | Implemented |
WV0257 # 11 Y:2003 | 11 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,974 | $6,300 | Implemented |
WV0257 # 12 Y:2003 | 12 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $19,542 | $1,375 | Implemented |
WV0257 # 13 Y:2003 | 13 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $538 | $2,900 | Implemented |
WV0257 # 14 Y:2003 | 14 | 2003 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $954 | $110 | Implemented |
UM0227 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,000 | $1,725 | Implemented |
UM0227 # 07 Y:2003 | 07 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,640 | $1,300 | Implemented |
SU0154 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $692 | $133 | Implemented |
SU0154 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $134 | $120 | Implemented |
SD0313 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,860 | $160 | Implemented |
SD0310 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,878 | $280 | Implemented |
SD0310 # 06 Y:2003 | 06 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,797 | $0 | Implemented |
SD0310 # 09 Y:2003 | 09 | 2003 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,770 | $0 | Implemented |
NC0251 # 04 Y:2002 | 04 | 2002 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $6,367 | $10,000 | Implemented |
NC0251 # 05 Y:2002 | 05 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,768 | $10,000 | Implemented |
NC0251 # 06 Y:2002 | 06 | 2002 | INSULATE BARE EQUIPMENT | $137 | $574 | Implemented |
CO0510 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,580 | $600 | Implemented |
CO0510 # 02 Y:2002 | 02 | 2002 | INSULATE BARE EQUIPMENT | $3,600 | $1,560 | Implemented |
CO0510 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $320 | $480 | Implemented |
CO0510 # 06 Y:2002 | 06 | 2002 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,900 | $250 | Implemented |
BD0214 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,378 | $700 | Implemented |
BD0214 # 09 Y:2002 | 09 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $222 | $215 | Implemented |
SD0300 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,870 | $520 | Implemented |
SD0300 # 06 Y:2002 | 06 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,500 | $10,000 | Implemented |