Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,137
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0482 # 04 Y:2001 | 04 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $990 | $370 | Implemented |
CO0482 # 06 Y:2001 | 06 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $310 | $60 | Implemented |
UD0617 # 01 Y:2001 | 01 | 2001 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $90,000 | $111,000 | Implemented |
UD0617 # 02 Y:2001 | 02 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $98,016 | $60,000 | Implemented |
UD0617 # 05 Y:2001 | 05 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,578 | $695 | Implemented |
SD0272 # 01 Y:2001 | 01 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,159 | $5,200 | Implemented |
SD0272 # 03 Y:2001 | 03 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $54,857 | $120,000 | Implemented |
SD0272 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,213 | $400 | Implemented |
SD0272 # 05 Y:2001 | 05 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,172 | $7,600 | Implemented |
SD0272 # 06 Y:2001 | 06 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,078 | $2,000 | Implemented |
UM0170 # 01 Y:2000 | 01 | 2000 | INSTALL OCCUPANCY SENSORS | $709 | $1,660 | Implemented |
UM0170 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,147 | $500 | Implemented |
MO0286 # 01 Y:2000 | 01 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,671 | $3,945 | Implemented |
MO0286 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,521 | $118 | Implemented |
MO0286 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,722 | $40 | Implemented |
MO0286 # 04 Y:2000 | 04 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $515 | $0 | Implemented |
MO0286 # 06 Y:2000 | 06 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,040 | $0 | Implemented |
MO0286 # 08 Y:2000 | 08 | 2000 | INSTALL EQUIPMENT TO MOVE PRODUCT | $3,650 | $1,300 | Implemented |
MO0286 # 09 Y:2000 | 09 | 2000 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $5,360 | $3,700 | Implemented |
CO0465 # 03 Y:2000 | 03 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,240 | $1,210 | Implemented |
CO0465 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,350 | $400 | Implemented |
CO0465 # 05 Y:2000 | 05 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $750 | $350 | Implemented |
CO0465 # 06 Y:2000 | 06 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $4,090 | $7,960 | Implemented |
AM0370 # 03 Y:2000 | 03 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $19,700 | $74,740 | Implemented |
AM0370 # 04 Y:2000 | 04 | 2000 | REDUCE OR ELIMINATE WASTE | $17,500 | $2,120 | Implemented |