Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,294
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0009 # 09 Y:2001 | 09 | 2001 | AUTOMATE PAYROLL SYSTEM | $37,300 | $9,195 | Implemented |
SU0106 # 01 Y:2001 | 01 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,051 | $0 | Implemented |
SU0106 # 04 Y:2001 | 04 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,158 | $500 | Implemented |
SU0106 # 05 Y:2001 | 05 | 2001 | OPTIMIZE PLANT POWER FACTOR | $3,243 | $10,210 | Implemented |
IC0007 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,050 | $2,125 | Implemented |
IC0007 # 03 Y:2001 | 03 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,066 | $195 | Implemented |
IC0007 # 08 Y:2001 | 08 | 2001 | CLEAR AND RENT EXISTING SPACE | $36,000 | $4,400 | Implemented |
SF0213 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,492 | $0 | Implemented |
SF0213 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $106 | $120 | Implemented |
SF0213 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $312 | $1,113 | Implemented |
UD0613 # 02 Y:2001 | 02 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $15,606 | $14,000 | Implemented |
UD0613 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,566 | $0 | Implemented |
UD0613 # 04 Y:2001 | 04 | 2001 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $5,513 | $5,000 | Implemented |
UD0613 # 05 Y:2001 | 05 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,342 | $0 | Implemented |
WV0208 # 05 Y:2001 | 05 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,573 | $203 | Implemented |
WV0208 # 01 Y:2001 | 01 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $13,153 | $950 | Implemented |
WV0208 # 02 Y:2001 | 02 | 2001 | USE SYNTHETIC LUBRICANT | $303 | $254 | Implemented |
WV0208 # 03 Y:2001 | 03 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $486 | $90 | Implemented |
WV0208 # 04 Y:2001 | 04 | 2001 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $633 | $340 | Implemented |
WV0208 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $1,754 | $138 | Implemented |
WV0208 # 08 Y:2001 | 08 | 2001 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $2,538 | $5,604 | Implemented |
WV0208 # 09 Y:2001 | 09 | 2001 | RECYCLE CLEANING SOLVENT AND REUSE | $2,056 | $8,000 | Implemented |
WV0208 # 10 Y:2001 | 10 | 2001 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $2,000 | $800 | Implemented |
WV0208 # 11 Y:2001 | 11 | 2001 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $896 | $100 | Implemented |
WV0208 # 13 Y:2001 | 13 | 2001 | EXPAND OPERATIONS INTO UNUSED SPACE | $42,527 | $36,400 | Implemented |