Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,321
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0509 # 01 Y:1996 | 01 | 1996 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,243 | $0 | Implemented |
OK0509 # 02 Y:1996 | 02 | 1996 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $14,966 | $18,000 | Implemented |
OK0509 # 04 Y:1996 | 04 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,419 | $855 | Implemented |
OK0509 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $470 | $460 | Implemented |
OK0509 # 06 Y:1996 | 06 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $538 | $248 | Implemented |
NV0069 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $235 | $100 | Implemented |
NV0069 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $678 | $100 | Implemented |
NV0069 # 03 Y:1996 | 03 | 1996 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $1,603 | $640 | Implemented |
NV0069 # 04 Y:1996 | 04 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,737 | $3,250 | Implemented |
NV0069 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,122 | $246 | Implemented |
NV0069 # 07 Y:1996 | 07 | 1996 | OPTIMIZE PLANT POWER FACTOR | $1,686 | $3,960 | Implemented |
UM0068 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $994 | $1,630 | Implemented |
UM0068 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,473 | $18,075 | Implemented |
UM0068 # 03 Y:1996 | 03 | 1996 | OPTIMIZE PLANT POWER FACTOR | $5,202 | $5,124 | Implemented |
UM0068 # 06 Y:1996 | 06 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $24,612 | $3,100 | Implemented |
SF0103 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $672 | $1,151 | Implemented |
SF0103 # 07 Y:1996 | 07 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $3,532 | $2,100 | Implemented |
SF0103 # 09 Y:1996 | 09 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $581 | $0 | Implemented |
SF0103 # 10 Y:1996 | 10 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,737 | $4,970 | Implemented |
SF0103 # 11 Y:1996 | 11 | 1996 | MINIMIZE WATER USAGE | $734 | $2,079 | Implemented |
NC0087 # 03 Y:1996 | 03 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $862 | $1,500 | Implemented |
NC0087 # 04 Y:1996 | 04 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,789 | $2,100 | Implemented |
NC0087 # 07 Y:1996 | 07 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $10,542 | $1,800 | Implemented |
NC0087 # 08 Y:1996 | 08 | 1996 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $94 | $750 | Implemented |
NC0087 # 09 Y:1996 | 09 | 1996 | SLOW INSERTION / WITHDRAWAL OF PARTS FROM DEGREASING TANK | $3,360 | $8,500 | Implemented |