Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,411
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TP0003 # 06 Y:1999 | 06 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $514 | $190 | Implemented |
TN0662 # 02 Y:1999 | 02 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $45,000 | $30,000 | Implemented |
TN0662 # 04 Y:1999 | 04 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $14,050 | $19,800 | Implemented |
TN0662 # 05 Y:1999 | 05 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,010 | $1,460 | Implemented |
SD0225 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,757 | $13,042 | Implemented |
SD0225 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,087 | $0 | Implemented |
SD0225 # 04 Y:1999 | 04 | 1999 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $704 | $400 | Implemented |
SD0225 # 05 Y:1999 | 05 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,845 | $240 | Implemented |
SD0225 # 06 Y:1999 | 06 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $11,820 | $0 | Implemented |
OR0342 # 01 Y:1999 | 01 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $135,000 | $29,120 | Implemented |
OR0342 # 02 Y:1999 | 02 | 1999 | $22,800 | $7,910 | Implemented | |
OR0342 # 03 Y:1999 | 03 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $81,500 | $126,000 | Implemented |
OR0342 # 04 Y:1999 | 04 | 1999 | AUTOMATE FINISHING PROCESS | $77,700 | $175,000 | Implemented |
OR0342 # 05 Y:1999 | 05 | 1999 | COMBINE UTILITY METERS | $1,100 | $5,000 | Implemented |
DS0138 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,384 | $998 | Implemented |
DS0138 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $629 | $875 | Implemented |
DS0138 # 05 Y:1999 | 05 | 1999 | UPGRADE CONTROLS ON COMPRESSORS | $1,165 | $241 | Implemented |
DS0138 # 07 Y:1999 | 07 | 1999 | INCREASE USE OF AUTOMATION | $96,760 | $65,000 | Implemented |
ND0319 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $63 | $65 | Implemented |
ND0319 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $411 | $30 | Implemented |
ND0319 # 06 Y:1999 | 06 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $155 | $40 | Implemented |
ND0319 # 07 Y:1999 | 07 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $283 | $510 | Implemented |
OK0572 # 02 Y:1999 | 02 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $884 | $96 | Implemented |
OK0572 # 03 Y:1999 | 03 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $746 | $225 | Implemented |
OK0572 # 06 Y:1999 | 06 | 1999 | INSTALL SET-BACK TIMERS | $1,177 | $1,116 | Implemented |