Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsSIC | 3679 | Electronic Components, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0508 # 08 Y:1996 | 08 | 1996 | $135,600 | $222,868 | Implemented | |
UD0508 # 10 Y:1996 | 10 | 1996 | RECOVER AND REUSE COOLING WATER | $5,108 | $5,000 | Implemented |
UD0508 # 09 Y:1996 | 09 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,158 | $2,286 | Implemented |
UD0508 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,088 | $2,314 | Implemented |
UD0508 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,041 | $8,081 | Implemented |
UD0508 # 04 Y:1996 | 04 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $31,719 | $11,000 | Implemented |
UD0508 # 06 Y:1996 | 06 | 1996 | ELIMINATE/REDUCE AN OPERATION | $8,523 | $0 | Implemented |
UD0508 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $7,200 | $60,000 | Implemented |
UD0508 # 07 Y:1996 | 07 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $101,584 | $40,000 | Implemented |
WI0285 # 03 Y:1996 | 03 | 1996 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,786 | $0 | Implemented |
AS0182 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,782 | $430 | Implemented |
AS0182 # 10 Y:1996 | 10 | 1996 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,490 | $1,200 | Implemented |
AS0182 # 07 Y:1996 | 07 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $23,483 | $35,000 | Implemented |
TN0590 # 02 Y:1996 | 02 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,400 | $0 | Implemented |
TN0590 # 01 Y:1996 | 01 | 1996 | USE PLASTIC PALLETS INSTEAD OF WOOD | $162,200 | $297,300 | Implemented |
TN0590 # 03 Y:1996 | 03 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,321 | $8,150 | Implemented |
TN0590 # 05 Y:1996 | 05 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $640 | $1,120 | Implemented |
MA0368 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,509 | $11,189 | Implemented |
MA0368 # 04 Y:1996 | 04 | 1996 | REPAIR OR REPLACE STEAM TRAPS | $1,990 | $868 | Implemented |
MA0368 # 06 Y:1996 | 06 | 1996 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $285 | $460 | Implemented |
AS0177 # 06 Y:1996 | 06 | 1996 | INSULATE BARE EQUIPMENT | $444 | $180 | Implemented |
DS0049 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $483 | $1,200 | Implemented |
DS0049 # 04 Y:1996 | 04 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $629 | $20 | Implemented |
DS0049 # 05 Y:1996 | 05 | 1996 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $25,792 | $80,000 | Implemented |
DS0049 # 06 Y:1996 | 06 | 1996 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $31,200 | $0 | Implemented |