IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,226

matching recommendations
Reset
SIC 37 Transportation Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0598 # 02 Y:2000 02 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,182 $700 Implemented
OK0598 # 05 Y:2000 05 2000 INSTALL SET-BACK TIMERS $535 $936 Implemented
UL0249 # 01 Y:2000 01 2000 INSTALL SKYLIGHTS $4,840 $5,700 Implemented
UL0249 # 02 Y:2000 02 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $1,210 $0 Implemented
UL0249 # 05 Y:2000 05 2000 COMBINE UTILITY METERS $3,900 $5,000 Implemented
ND0363 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,021 $8,040 Implemented
ND0363 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,260 $520 Implemented
ND0363 # 05 Y:2000 05 2000 PAY UTILITY BILLS ON TIME $1,211 $0 Implemented
ND0362 # 01 Y:2000 01 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $17,460 $200 Implemented
ND0362 # 05 Y:2000 05 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $491 $40 Implemented
ND0362 # 07 Y:2000 07 2000 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,034 $0 Implemented
UD0609 # 04 Y:2000 04 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $163 $0 Implemented
SF0199 # 01 Y:2000 01 2000 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $584 $0 Implemented
SF0199 # 02 Y:2000 02 2000 MODERATE COOLING TOWER OUTLET TEMPERATURE $4,250 $850 Implemented
SF0199 # 05 Y:2000 05 2000 INSTALL OCCUPANCY SENSORS $1,079 $1,080 Implemented
SF0199 # 06 Y:2000 06 2000 INSTALL OCCUPANCY SENSORS $1,583 $2,000 Implemented
SF0199 # 07 Y:2000 07 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $12,739 $36,345 Implemented
SF0199 # 08 Y:2000 08 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,178 $13,460 Implemented
SF0198 # 01 Y:2000 01 2000 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $1,396 $4,740 Implemented
SF0198 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $307 $600 Implemented
SF0198 # 03 Y:2000 03 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $215 $0 Implemented
SF0198 # 04 Y:2000 04 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $412 $1,992 Implemented
SF0198 # 05 Y:2000 05 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,299 $4,199 Implemented
SF0198 # 06 Y:2000 06 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,800 $80 Implemented
SF0198 # 07 Y:2000 07 2000 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $24,608 $3,400 Implemented