Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

338

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0014 # 05 Y:1994 05 1994 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $105 $56 Not Implemented
UL0115 # 03 Y:1994 03 1994 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $4,013 $4,000 Implemented
ND0200 # 02 Y:1994 02 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,112 $1,500 Not Implemented
ND0200 # 09 Y:1994 09 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,402 $5,000 Not Implemented
UL0115 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,505 $2,000 Not Implemented
ND0205 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $418 $500 Implemented
SF0045 # 04 Y:1994 04 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $11,628 $9,140 Implemented
SF0045 # 05 Y:1994 05 1994 ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES $386 $300 Implemented
GT0546 # 03 Y:1994 03 1994 ADJUST BURNERS FOR EFFICIENT OPERATION $3,540 $500 Not Implemented
UL0114 # 03 Y:1994 03 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,769 $2,000 Not Implemented
OR0225 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $18,649 $500 Implemented
ND0206 # 10 Y:1994 10 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $181 $600 n/a
WI0221 # 07 Y:1994 07 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $138 $500 Implemented
AM0225 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $13,670 $15,000 Implemented
UD0447 # 03 Y:1994 03 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,206 $1,000 Implemented
GT0544 # 07 Y:1994 07 1994 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $1,905 $4,800 Not Implemented
UL0113 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,294 $1,500 Implemented
SF0044 # 03 Y:1994 03 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,035 $5,600 Not Implemented
UD0447 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,160 $5,000 Not Implemented
GT0543 # 03 Y:1994 03 1994 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $2,530 $7,185 Not Implemented
MO0134 # 05 Y:1994 05 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,574 $4,266 Not Implemented
BD0014 # 01 Y:1994 01 1994 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $206,117 $508,700 Not Implemented
BD0014 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,879 $7,000 Not Implemented
WI0220 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,005 $500 Not Implemented
UD0445 # 05 Y:1994 05 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,835 $10,000 Implemented