Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

178

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0128 # 03 Y:1994 03 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $474 $995 Implemented
MO0128 # 02 Y:1994 02 1994 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $27,900 $525 Implemented
SF0037 # 08 Y:1994 08 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,046 $500 Implemented
ME0142 # 10 Y:1994 10 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $583 $400 Implemented
WI0215 # 05 Y:1994 05 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $229 $500 Implemented
WI0214 # 07 Y:1994 07 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,682 $500 Implemented
ME0141 # 05 Y:1994 05 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $619 $400 Implemented
AS0125 # 07 Y:1994 07 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $659 $1,000 Not Implemented
KG0007 # 04 Y:1994 04 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,156 $100 Not Implemented
UL0106 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,326 $2,000 Not Implemented
KU0435 # 01 Y:1994 01 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $6,681 $1,800 Not Implemented
OR0214 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,849 $500 Implemented
AR0032 # 06 Y:1994 06 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $33,863 $1,000 Implemented
WV0041 # 03 Y:1994 03 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $423 $500 Not Implemented
IA0090 # 06 Y:1994 06 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $4,490 $12,600 Implemented
WV0041 # 04 Y:1994 04 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $6,040 $3,440 Not Implemented
AR0031 # 07 Y:1994 07 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,503 $1,000 Implemented
MO0125 # 08 Y:1994 08 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,568 $995 Not Implemented
KG0005 # 05 Y:1994 05 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,042 $2,500 Implemented
TN0523 # 08 Y:1994 08 1994 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $21,222 $16,000 Not Implemented
NC0032 # 05 Y:1994 05 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $269 $75 Not Implemented
WI0209 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,085 $500 Implemented
UM0009 # 08 Y:1994 08 1994 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $9,325 $6,000 Not Implemented
WV0039 # 03 Y:1994 03 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $77,346 $5,000 Implemented
WV0038 # 04 Y:1994 04 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $81,877 $4,570 Not Implemented