Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,018
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0166 # 03 Y:2016 | 03 | 2016 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,496 | $9,820 | Not Implemented |
SD0536 # 05 Y:2016 | 05 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,594 | $11,180 | Not Implemented |
SD0536 # 08 Y:2016 | 08 | 2016 | INSULATE BARE EQUIPMENT | $1,796 | $2,742 | Implemented |
UD0953 # 01 Y:2016 | 01 | 2016 | INSULATE BARE EQUIPMENT | $5,190 | $348 | Not Implemented |
TT0177 # 04 Y:2016 | 04 | 2016 | INSULATE BARE EQUIPMENT | $2,669 | $1,720 | Not Implemented |
TT0177 # 06 Y:2016 | 06 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,002 | $1,400 | Implemented |
UA0166 # 03 Y:2016 | 03 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $26,248 | $80 | Implemented |
UA0166 # 05 Y:2016 | 05 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,707 | $120 | Implemented |
SD0535 # 07 Y:2016 | 07 | 2016 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $710 | $3,100 | Not Implemented |
AM0713 # 01 Y:2016 | 01 | 2016 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $453,910 | $3,100,000 | Not Implemented |
MA0758 # 01 Y:2016 | 01 | 2016 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $2,549 | $2,836 | Implemented |
MA0760 # 04 Y:2016 | 04 | 2016 | INSULATE BARE EQUIPMENT | $520 | $62 | Not Implemented |
SD0534 # 05 Y:2016 | 05 | 2016 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $2,674 | $2,863 | Not Implemented |
WV0530 # 01 Y:2016 | 01 | 2016 | INSULATE BARE EQUIPMENT | $45,649 | $8,838 | Implemented |
WV0530 # 08 Y:2016 | 08 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,395 | $27,920 | Not Implemented |
MA0761 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $22,997 | $134,000 | Not Implemented |
MA0761 # 05 Y:2016 | 05 | 2016 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $864 | $342 | Not Implemented |
BS0079 # 01 Y:2016 | 01 | 2016 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,545 | $6,216 | Not Implemented |
BS0079 # 03 Y:2016 | 03 | 2016 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $232 | $850 | Not Implemented |
UA0165 # 05 Y:2016 | 05 | 2016 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $11,135 | $28,500 | Not Implemented |
LE0422 # 12 Y:2016 | 12 | 2016 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $55,094 | $185,000 | Not Implemented |
CO0725 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $6,010 | $620 | n/a |
UD0952 # 03 Y:2016 | 03 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,277 | $0 | Not Implemented |
UD0952 # 05 Y:2016 | 05 | 2016 | INSULATE FEEDWATER TANK | $983 | $509 | Not Implemented |
UD0952 # 12 Y:2016 | 12 | 2016 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $9,559 | $23,200 | Not Implemented |