Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

525

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0212 # 02 Y:2001 02 2001 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $5,740 $5,000 Not Implemented
NC0212 # 03 Y:2001 03 2001 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $2,554 $11,000 Not Implemented
NC0212 # 05 Y:2001 05 2001 USE OPTIMUM THICKNESS INSULATION $3,300 $5,000 Not Implemented
NC0212 # 08 Y:2001 08 2001 RECOVER WASTE HEAT FROM EQUIPMENT $6,950 $8,846 Not Implemented
GT0712 # 01 Y:2001 01 2001 USE MINIMUM STEAM OPERATING PRESSURE $50,880 $75,000 n/a
GT0712 # 02 Y:2001 02 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $45,320 $55,800 n/a
GT0712 # 06 Y:2001 06 2001 INSULATE BARE EQUIPMENT $152,112 $51,570 n/a
GT0712 # 07 Y:2001 07 2001 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $101,860 $27,240 n/a
LE0109 # 06 Y:2001 06 2001 INSTALL STEAM TRAP $1,932 $1,000 Implemented
LE0109 # 07 Y:2001 07 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $303 $610 Implemented
MA0486 # 03 Y:2001 03 2001 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $4,300 $25,000 Not Implemented
MA0486 # 05 Y:2001 05 2001 RECOVER WASTE HEAT FROM EQUIPMENT $1,700 $5,000 Implemented
MA0486 # 06 Y:2001 06 2001 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,400 $8,000 Not Implemented
SD0277 # 03 Y:2001 03 2001 RECOVER WASTE HEAT FROM EQUIPMENT $11,030 $5,000 Not Implemented
SD0277 # 07 Y:2001 07 2001 INSULATE BARE EQUIPMENT $3,648 $7,000 Implemented
NC0211 # 03 Y:2001 03 2001 USE MINIMUM STEAM OPERATING PRESSURE $2,014 $250 Implemented
GT0711 # 07 Y:2001 07 2001 CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING $140 $800 Not Implemented
OK0612 # 05 Y:2001 05 2001 REPAIR AND ELIMINATE STEAM LEAKS $1,650 $720 Implemented
TA0005 # 02 Y:2001 02 2001 INCREASE AMOUNT OF CONDENSATE RETURNED $55,066 $8,241 n/a
TA0005 # 03 Y:2001 03 2001 REDUCE EXCESS STEAM BLEEDING $32,800 $156 Not Implemented
TA0005 # 04 Y:2001 04 2001 REPAIR AND ELIMINATE STEAM LEAKS $31,880 $1,080 Implemented
TA0005 # 06 Y:2001 06 2001 REDUCE EXCESS STEAM BLEEDING $14,571 $155 Implemented
TA0005 # 07 Y:2001 07 2001 INSULATE BARE EQUIPMENT $14,688 $20,194 Implemented
TA0005 # 08 Y:2001 08 2001 SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM $6,882 $820 Implemented
TA0005 # 12 Y:2001 12 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $1,855 $277 Implemented