Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

605

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0335 # 02 Y:1995 02 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,479 $3,771 Not Implemented
KU0453 # 01 Y:1995 01 1995 RECOVER WASTE HEAT FROM EQUIPMENT $2,320 $17,800 Not Implemented
NV0027 # 06 Y:1995 06 1995 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $605 $112 Not Implemented
OD0027 # 01 Y:1995 01 1995 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $41,731 $48,000 Implemented
ND0208 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $9,644 $500 Not Implemented
UD0456 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $10,700 $24,000 Implemented
AM0240 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $670 $835 Implemented
BD0025 # 02 Y:1995 02 1995 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $4,321 $8,450 Not Implemented
BD0025 # 05 Y:1995 05 1995 RECOVER WASTE HEAT FROM EQUIPMENT $4,840 $2,500 Implemented
NV0026 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $1,356 $60 Not Implemented
NV0026 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $512 $320 Implemented
NV0026 # 07 Y:1995 07 1995 REPAIR AND ELIMINATE STEAM LEAKS $468 $20 Not Implemented
WV0058 # 02 Y:1995 02 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $2,841 $0 Implemented
MA0334 # 04 Y:1995 04 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,019 $2,605 Implemented
WI0232 # 02 Y:1995 02 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,343 $10,000 Not Implemented
UD0455 # 07 Y:1995 07 1995 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $4,193 $3,000 Not Implemented
SD0112 # 02 Y:1995 02 1995 COVER OPEN TANKS $1,015 $250 Implemented
SD0112 # 03 Y:1995 03 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,144 $1,600 Implemented
SD0112 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $2,282 $563 Implemented
CO0328 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $2,390 $1,710 Not Implemented
GT0551 # 04 Y:1995 04 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $34,790 $16,500 Implemented
ME0155 # 03 Y:1995 03 1995 CLOSE OFF UNNEEDED STEAM LINES $1,120 $200 Implemented
ME0155 # 04 Y:1995 04 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $952 $350 Implemented
ME0155 # 06 Y:1995 06 1995 USE OPTIMUM THICKNESS INSULATION $772 $130 Implemented
AM0237 # 03 Y:1995 03 1995 INSULATE BARE EQUIPMENT $2,700 $620 Implemented