Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,022

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0577 # 02 Y:2012 02 2012 INSTALL / REPAIR INSULATION ON STEAM LINES $2,191 $1,404 Implemented
GT0889 # 02 Y:2012 02 2012 REPAIR OR REPLACE STEAM TRAPS $14,795 $8,500 Not Implemented
GT0889 # 03 Y:2012 03 2012 INSULATE BARE EQUIPMENT $4,743 $3,920 Not Implemented
GT0889 # 04 Y:2012 04 2012 REDUCE EXCESS STEAM BLEEDING $19,253 $45,075 Not Implemented
UD0847 # 05 Y:2012 05 2012 RECOVER WASTE HEAT FROM EQUIPMENT $2,953 $1,500 Not Implemented
UD0847 # 09 Y:2012 09 2012 INSULATE BARE EQUIPMENT $175 $200 Not Implemented
UF0452 # 01 Y:2012 01 2012 INSULATE BARE EQUIPMENT $11,846 $20,077 Not Implemented
BD0406 # 02 Y:2012 02 2012 RECOVER WASTE HEAT FROM EQUIPMENT $15,397 $800 Not Implemented
BD0406 # 04 Y:2012 04 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,394 $3,000 Implemented
IA0475 # 04 Y:2012 04 2012 INSTALL / REPAIR INSULATION ON STEAM LINES $1,097 $1,375 Not Implemented
IA0475 # 06 Y:2012 06 2012 RECOVER WASTE HEAT FROM EQUIPMENT $2,229 $16,000 Not Implemented
IA0475 # 08 Y:2012 08 2012 RECOVER WASTE HEAT FROM EQUIPMENT $4,902 $4,500 Not Implemented
UMS003 # 01 Y:2012 01 2012 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $99,533 $120,000 Not Implemented
UMS002 # 01 Y:2012 01 2012 INSULATE BARE EQUIPMENT $1,300 $1,000 Not Implemented
SF0406 # 03 Y:2012 03 2012 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $2,483 $0 Implemented
SF0406 # 07 Y:2012 07 2012 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $90,076 $288,023 Not Implemented
UA0072 # 01 Y:2012 01 2012 RECOVER WASTE HEAT FROM EQUIPMENT $17,176 $2,039 Implemented
UD0846 # 07 Y:2012 07 2012 INSULATE BARE EQUIPMENT $249 $593 Not Implemented
UD0846 # 08 Y:2012 08 2012 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $11,712 $38,000 Implemented
SF0405 # 02 Y:2012 02 2012 REPAIR OR REPLACE STEAM TRAPS $76,949 $36,149 Implemented
SF0405 # 03 Y:2012 03 2012 INCREASE AMOUNT OF CONDENSATE RETURNED $139,563 $85,532 Implemented
SF0405 # 05 Y:2012 05 2012 INSULATE BARE EQUIPMENT $38,824 $39,132 Not Implemented
UMS001 # 03 Y:2012 03 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $938,000 $1,000,000 Not Implemented
BD0404 # 03 Y:2012 03 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $28,023 $25,000 Not Implemented
BD0404 # 07 Y:2012 07 2012 REPAIR AND ELIMINATE STEAM LEAKS $1,669 $100 Implemented