Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,022

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0805 # 02 Y:2011 02 2011 INCREASE AMOUNT OF CONDENSATE RETURNED $21,982 $8,893 Not Implemented
MS0364 # 04 Y:2011 04 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $10,791 $20,863 Not Implemented
TT0063 # 02 Y:2011 02 2011 REPAIR OR REPLACE STEAM TRAPS $6,712 $4,800 Not Implemented
TT0063 # 04 Y:2011 04 2011 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $900 $1,050 Implemented
TT0063 # 06 Y:2011 06 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $12,516 $4,000 Not Implemented
SF0393 # 02 Y:2011 02 2011 RECOVER WASTE HEAT FROM EQUIPMENT $99,396 $33,822 Implemented
SF0393 # 05 Y:2011 05 2011 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $153,800 $220,659 Not Implemented
SF0393 # 08 Y:2011 08 2011 INSULATE BARE EQUIPMENT $6,132 $17,178 Implemented
LL0343 # 01 Y:2011 01 2011 REPAIR AND ELIMINATE STEAM LEAKS $106,373 $5,110 Implemented
LL0343 # 04 Y:2011 04 2011 INSULATE BARE EQUIPMENT $5,155 $2,526 Implemented
WV0422 # 07 Y:2011 07 2011 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $1,500 $2,875 Not Implemented
WV0422 # 10 Y:2011 10 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $750 $329 Not Implemented
WV0421 # 03 Y:2011 03 2011 COVER OPEN TANKS $15,551 $3,659 Not Implemented
WV0421 # 04 Y:2011 04 2011 RECOVER WASTE HEAT FROM EQUIPMENT $6,529 $2,469 Implemented
WV0421 # 05 Y:2011 05 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,567 $10,314 Not Implemented
WV0421 # 08 Y:2011 08 2011 INSULATE BARE EQUIPMENT $4,166 $1,910 Implemented
WV0421 # 11 Y:2011 11 2011 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $2,484 $8,964 Not Implemented
GT0879 # 06 Y:2011 06 2011 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $339,042 $1,340,000 Not Implemented
TT0059 # 04 Y:2011 04 2011 RECOVER WASTE HEAT FROM EQUIPMENT $6,500 $7,500 Not Implemented
OK0804 # 02 Y:2011 02 2011 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $64,961 $238,050 Not Implemented
OK0804 # 03 Y:2011 03 2011 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $12,835 $19,625 Not Implemented
OK0804 # 13 Y:2011 13 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,107 $19,271 Not Implemented
UW0045 # 04 Y:2011 04 2011 INSULATE BARE EQUIPMENT $5,260 $220 Implemented
AM0594 # 05 Y:2011 05 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $650 $270 Implemented
SU0303 # 01 Y:2011 01 2011 INSULATE FEEDWATER TANK $273 $83 Implemented