Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,028

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0014 # 06 Y:2008 06 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,200 $20,000 Not Implemented
NC0378 # 05 Y:2008 05 2008 RECOVER WASTE HEAT FROM EQUIPMENT $17,355 $7,450 Not Implemented
TT0026 # 07 Y:2008 07 2008 INSULATE BARE EQUIPMENT $25,000 $1,000 Not Implemented
UF0414 # 06 Y:2008 06 2008 REPAIR AND ELIMINATE STEAM LEAKS $2,447 $371 Implemented
UF0414 # 07 Y:2008 07 2008 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $13,994 $10,000 Not Implemented
MA0642 # 02 Y:2008 02 2008 RECOVER WASTE HEAT FROM EQUIPMENT $4,095 $4,354 Not Implemented
SF0361 # 05 Y:2008 05 2008 INSULATE BARE EQUIPMENT $1,614 $1,036 Implemented
SF0361 # 06 Y:2008 06 2008 HEAT WATER WITH EXHAUST HEAT $24,668 $16,423 Not Implemented
MZ0022 # 03 Y:2008 03 2008 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $11,853 $5,458 Implemented
MZ0023 # 01 Y:2008 01 2008 INSULATE BARE EQUIPMENT $183 $80 Implemented
MZ0023 # 05 Y:2008 05 2008 REPAIR OR REPLACE STEAM TRAPS $47,858 $40,000 Implemented
MS0330 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $21,490 $1,800 Implemented
MS0330 # 05 Y:2008 05 2008 REPAIR AND ELIMINATE STEAM LEAKS $2,517 $94 Not Implemented
UF0413 # 07 Y:2008 07 2008 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $12,742 $20,000 Not Implemented
LL0297 # 03 Y:2008 03 2008 REPAIR AND ELIMINATE STEAM LEAKS $4,566 $730 Implemented
LL0297 # 06 Y:2008 06 2008 INSULATE BARE EQUIPMENT $802 $930 Not Implemented
DL0015 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $20,000 $400 Not Implemented
DL0015 # 05 Y:2008 05 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $5,911 $2,500 Implemented
DL0015 # 06 Y:2008 06 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,000 $16,000 Not Implemented
DL0015 # 09 Y:2008 09 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $2,970 $10,000 Not Implemented
LL0296 # 05 Y:2008 05 2008 INSULATE BARE EQUIPMENT $4,739 $3,400 Not Implemented
SU0270 # 03 Y:2008 03 2008 REPAIR AND ELIMINATE STEAM LEAKS $48,133 $1,453 Implemented
SU0270 # 07 Y:2008 07 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $23,234 $18,896 Implemented
SU0270 # 08 Y:2008 08 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $392 $430 Implemented
MA0639 # 07 Y:2008 07 2008 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $7,426 $27,000 Implemented