Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,028
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0400 # 07 Y:2007 | 07 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $653 | $511 | Not Implemented |
UF0399 # 02 Y:2007 | 02 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $349 | $1,376 | Not Implemented |
UF0399 # 05 Y:2007 | 05 | 2007 | USE OPTIMUM THICKNESS INSULATION | $1,157 | $188 | Not Implemented |
UF0399 # 08 Y:2007 | 08 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $47,277 | $35,000 | Not Implemented |
TT0003 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,379 | $1,500 | Not Implemented |
TT0003 # 07 Y:2007 | 07 | 2007 | INSULATE BARE EQUIPMENT | $5,016 | $1,000 | Not Implemented |
LE0254 # 01 Y:2007 | 01 | 2007 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $81,900 | $65,000 | Not Implemented |
LE0254 # 02 Y:2007 | 02 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $67,570 | $67,000 | Not Implemented |
LE0254 # 05 Y:2007 | 05 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $7,471 | $800 | Not Implemented |
LE0254 # 07 Y:2007 | 07 | 2007 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $3,029 | $800 | Not Implemented |
NC0362 # 01 Y:2007 | 01 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $43,646 | $70,525 | Not Implemented |
NC0362 # 02 Y:2007 | 02 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $75,775 | $79,525 | Not Implemented |
NC0361 # 03 Y:2007 | 03 | 2007 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $6,894 | $19,950 | Not Implemented |
NC0361 # 11 Y:2007 | 11 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $376 | $1,000 | Not Implemented |
LE0255 # 03 Y:2007 | 03 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $23,595 | $5,000 | Implemented |
SF0343 # 01 Y:2007 | 01 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,112 | $220 | Implemented |
SF0343 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,925 | $6,063 | Implemented |
IC0127 # 07 Y:2007 | 07 | 2007 | INSULATE BARE EQUIPMENT | $3,818 | $886 | Implemented |
IC0127 # 08 Y:2007 | 08 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $2,137 | $1,000 | Implemented |
IC0127 # 10 Y:2007 | 10 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $22,675 | $50,711 | Implemented |
BD0326 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,125 | $1,200 | Not Implemented |
BD0326 # 10 Y:2007 | 10 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $270 | $150 | Not Implemented |
SU0251 # 06 Y:2007 | 06 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $2,314 | $219 | Implemented |
SU0251 # 08 Y:2007 | 08 | 2007 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $38,999 | $17,176 | Not Implemented |
SU0251 # 09 Y:2007 | 09 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,026 | $5,000 | Implemented |