Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,028
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0251 # 10 Y:2007 | 10 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $278 | $130 | Not Implemented |
OK0746 # 01 Y:2007 | 01 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $32,026 | $30,757 | Implemented |
SU0251 # 09 Y:2007 | 09 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,026 | $5,000 | Implemented |
UD0762 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,706 | $7,000 | Not Implemented |
UD0762 # 03 Y:2007 | 03 | 2007 | INSULATE BARE EQUIPMENT | $22,493 | $9,310 | Not Implemented |
MA0618 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,316 | $3,220 | Implemented |
MA0618 # 06 Y:2007 | 06 | 2007 | INSULATE BARE EQUIPMENT | $7,795 | $1,924 | Implemented |
MA0618 # 09 Y:2007 | 09 | 2007 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $1,070 | $340 | Implemented |
IA0406 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $507 | $100 | Implemented |
IA0406 # 04 Y:2007 | 04 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,396 | $1,000 | Not Implemented |
UA0003 # 03 Y:2007 | 03 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $43,286 | $20,950 | Not Implemented |
UA0003 # 01 Y:2007 | 01 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $65,640 | $16,926 | Not Implemented |
UA0003 # 06 Y:2007 | 06 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,422 | $0 | Not Implemented |
LL0274 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $29,800 | $1,169 | Implemented |
OK0745 # 03 Y:2007 | 03 | 2007 | INSULATE BARE EQUIPMENT | $13,884 | $4,859 | Implemented |
OK0745 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $2,384 | $744 | Not Implemented |
LE0253 # 06 Y:2007 | 06 | 2007 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $12,436 | $15,000 | Not Implemented |
OK0745 # 09 Y:2007 | 09 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,516 | $7,600 | Not Implemented |
UD0761 # 05 Y:2007 | 05 | 2007 | COVER OPEN TANKS | $12,478 | $1,243 | Not Implemented |
UD0761 # 04 Y:2007 | 04 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $15,090 | $93,600 | Implemented |
UD0761 # 06 Y:2007 | 06 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $4,701 | $4,500 | Not Implemented |
SF0342 # 09 Y:2007 | 09 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,865 | $13,500 | Not Implemented |
SF0342 # 01 Y:2007 | 01 | 2007 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $250,944 | $80,000 | Not Implemented |
SF0342 # 03 Y:2007 | 03 | 2007 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $8,746 | $7,500 | Implemented |
SF0342 # 08 Y:2007 | 08 | 2007 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $130,413 | $250,000 | Not Implemented |