Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19,997

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0498 # 02 Y:1993 02 1993 COVER OPEN TANKS $12,312 $7,480 Implemented
TN0498 # 04 Y:1993 04 1993 USE MINIMUM STEAM OPERATING PRESSURE $7,649 $0 Not Implemented
TN0498 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $2,696 $8,300 Implemented
TN0498 # 10 Y:1993 10 1993 INSULATE BARE EQUIPMENT $478 $193 Implemented
MA0275 # 03 Y:1993 03 1993 INSULATE BARE EQUIPMENT $1,813 $643 Not Implemented
WI0180 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $2,007 $51 Implemented
WI0180 # 11 Y:1993 11 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,167 $10,000 Not Implemented
GT0492 # 02 Y:1993 02 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,880 $11,800 Not Implemented
GT0492 # 03 Y:1993 03 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,620 $7,280 Not Implemented
SF0002 # 03 Y:1993 03 1993 RECOVER WASTE HEAT FROM EQUIPMENT $793 $1,150 Not Implemented
KU0398 # 01 Y:1993 01 1993 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $45,950 $48,000 Not Implemented
KU0398 # 02 Y:1993 02 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $17,158 $19,000 Not Implemented
UD0403 # 01 Y:1993 01 1993 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $17,544 $50,000 Implemented
MA0274 # 05 Y:1993 05 1993 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $687 $169 Not Implemented
SD0059 # 01 Y:1993 01 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $253 $351 Not Implemented
SD0059 # 02 Y:1993 02 1993 USE OPTIMUM THICKNESS INSULATION $251 $243 Not Implemented
SD0059 # 03 Y:1993 03 1993 USE OPTIMUM THICKNESS INSULATION $495 $232 Not Implemented
ND0153 # 04 Y:1993 04 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $12,527 $1,413 Not Implemented
ND0153 # 07 Y:1993 07 1993 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $225 $218 Implemented
OK0410 # 02 Y:1993 02 1993 RECOVER WASTE HEAT FROM EQUIPMENT $1,645 $1,070 Not Implemented
AR0002 # 04 Y:1993 04 1993 REPAIR AND ELIMINATE STEAM LEAKS $1,845 $475 Implemented
WV0003 # 06 Y:1993 06 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $20,126 $2,100 Not Implemented
WV0003 # 08 Y:1993 08 1993 ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA $4,966 $1,790 Not Implemented
UD0402 # 04 Y:1993 04 1993 RECOVER WASTE HEAT FROM EQUIPMENT $4,680 $1,500 Implemented
CO0275 # 01 Y:1993 01 1993 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $7,880 $12,500 Not Implemented