Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
483
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0078 # 08 Y:2011 | 08 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $23,761 | $22,500 | Not Implemented |
MZ0073 # 04 Y:2011 | 04 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,393 | $4,500 | Not Implemented |
UA0071 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,837 | $1,752 | Not Implemented |
MS0385 # 01 Y:2011 | 01 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,422 | $5,076 | Not Implemented |
WV0439 # 10 Y:2011 | 10 | 2011 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $4,477 | $144 | Implemented |
UA0069 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $678 | $2,578 | Not Implemented |
WV0439 # 13 Y:2011 | 13 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,536 | $9,580 | Not Implemented |
UA0069 # 06 Y:2011 | 06 | 2011 | USE OPTIMUM THICKNESS INSULATION | $25,829 | $16,900 | Not Implemented |
WV0439 # 11 Y:2011 | 11 | 2011 | INSULATE BARE EQUIPMENT | $4,234 | $972 | Implemented |
UA0069 # 07 Y:2011 | 07 | 2011 | USE OPTIMUM THICKNESS INSULATION | $5,314 | $1,750 | Not Implemented |
UA0069 # 08 Y:2011 | 08 | 2011 | USE OPTIMUM THICKNESS INSULATION | $6,558 | $7,600 | Not Implemented |
WV0438 # 06 Y:2011 | 06 | 2011 | INSULATE BARE EQUIPMENT | $10,092 | $2,424 | Not Implemented |
WV0438 # 02 Y:2011 | 02 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,986 | $25,242 | Not Implemented |
WV0438 # 03 Y:2011 | 03 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $23,750 | $68,377 | Not Implemented |
MZ0077 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,741 | $28,000 | Not Implemented |
UD0844 # 12 Y:2011 | 12 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,508 | $16,000 | Not Implemented |
UD0844 # 13 Y:2011 | 13 | 2011 | USE OPTIMUM TEMPERATURE | $3,225 | $0 | Not Implemented |
OK0818 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,355 | $4,015 | Not Implemented |
GT0887 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,716 | $2,500 | Implemented |
UF0451 # 07 Y:2011 | 07 | 2011 | ISOLATE STEAM LINES TO AVOID HEATING AIR CONDITIONED AREAS | $1,379 | $1,140 | Not Implemented |
UF0451 # 08 Y:2011 | 08 | 2011 | USE OPTIMUM THICKNESS INSULATION | $1,327 | $1,865 | Not Implemented |
BD0401 # 04 Y:2011 | 04 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,685 | $3,000 | Not Implemented |
LL0361 # 09 Y:2011 | 09 | 2011 | INSULATE BARE EQUIPMENT | $85 | $345 | Not Implemented |
UM0397 # 02 Y:2011 | 02 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,335 | $30,200 | Not Implemented |
MA0682 # 01 Y:2011 | 01 | 2011 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $29,366 | $91,950 | Not Implemented |