Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

46,660

matching recommendations
Reset
ARC 2.7 Building and Grounds
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0217 # 02 Y:1987 02 1987 REDUCE GLAZED AREAS IN BUILDINGS $3,993 $20,000 Implemented
UD0218 # 01 Y:1987 01 1987 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $19,049 $5,470 Implemented
TN0278 # 01 Y:1986 01 1986 INSTALL TIMERS AND/OR THERMOSTATS $6,537 $2,810 Not Implemented
TN0278 # 02 Y:1986 02 1986 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $4,026 $4,844 Not Implemented
TN0293 # 03 Y:1986 03 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,536 $0 Not Implemented
TN0293 # 08 Y:1986 08 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,279 $300 Not Implemented
TN0294 # 01 Y:1986 01 1986 INSTALL TIMERS AND/OR THERMOSTATS $10,135 $2,675 Implemented
TN0295 # 01 Y:1986 01 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,892 $48,000 Not Implemented
MA0077 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $659 $212 Not Implemented
MA0077 # 03 Y:1986 03 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,888 $4,650 Not Implemented
MA0077 # 05 Y:1986 05 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $17,850 $22,500 Not Implemented
MA0077 # 08 Y:1986 08 1986 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $5,082 $0 Not Implemented
LT0052 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,660 $1,476 Implemented
LT0052 # 03 Y:1986 03 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,795 $4,990 Implemented
LT0052 # 05 Y:1986 05 1986 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $735 $770 Not Implemented
LT0052 # 07 Y:1986 07 1986 PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT $556 $1,470 Not Implemented
LT0069 # 01 Y:1986 01 1986 INSTALL TIMERS AND/OR THERMOSTATS $1,700 $1,350 Implemented
LT0069 # 02 Y:1986 02 1986 AIR CONDITION ONLY SPACE NECESSARY $590 $0 Implemented
LT0069 # 04 Y:1986 04 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $899 $150 Implemented
LT0069 # 06 Y:1986 06 1986 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,930 $2,160 Not Implemented
CO0075 # 08 Y:1986 08 1986 USE RADIANT HEATER FOR SPOT HEATING $3,692 $9,100 Not Implemented
CO0075 # 10 Y:1986 10 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $366 $892 Not Implemented
CO0075 # 11 Y:1986 11 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,813 $903 Not Implemented
CO0076 # 01 Y:1986 01 1986 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $3,878 $200 Implemented
CO0076 # 03 Y:1986 03 1986 USE RADIANT HEATER FOR SPOT HEATING $2,349 $7,000 Implemented