Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,292
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0221 # 01 Y:2024 | 01 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $13,280 | $0 | n/a |
WM0221 # 02 Y:2024 | 02 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,591 | $9,372 | n/a |
WM0221 # 03 Y:2024 | 03 | 2024 | INSTALL OCCUPANCY SENSORS | $3,845 | $0 | n/a |
WM0221 # 04 Y:2024 | 04 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,436 | $0 | n/a |
WM0221 # 05 Y:2024 | 05 | 2024 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,454 | $2,360 | n/a |
UW2407 # 05 Y:2024 | 05 | 2024 | INSTALL OCCUPANCY SENSORS | $2,085 | $28,384 | n/a |
UW2407 # 06 Y:2024 | 06 | 2024 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,140 | $14,800 | n/a |
KS2430 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,174 | $9,216 | n/a |
LE0563 # 02 Y:2024 | 02 | 2024 | INSTALL TIMERS AND/OR THERMOSTATS | $2,648 | $960 | n/a |
LE0563 # 03 Y:2024 | 03 | 2024 | INSTALL OCCUPANCY SENSORS | $307 | $140 | n/a |
LE0563 # 05 Y:2024 | 05 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,800 | $19,440 | n/a |
LE0563 # 06 Y:2024 | 06 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,361 | $21,000 | n/a |
LE0563 # 07 Y:2024 | 07 | 2024 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $1,253 | $9,000 | n/a |
LE0563 # 08 Y:2024 | 08 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $222 | $1,600 | n/a |
NT0024 # 05 Y:2024 | 05 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,083 | $5,482 | n/a |
NT0024 # 06 Y:2024 | 06 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $351 | $180 | n/a |
KS2429 # 05 Y:2024 | 05 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,984 | $26,926 | n/a |
KS2429 # 06 Y:2024 | 06 | 2024 | INSTALL OCCUPANCY SENSORS | $6,211 | $6,604 | n/a |
IC0301 # 06 Y:2024 | 06 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,487 | $0 | n/a |
IP0190 # 06 Y:2024 | 06 | 2024 | INSTALL OCCUPANCY SENSORS | $1,572 | $559 | n/a |
IP0190 # 07 Y:2024 | 07 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,128 | $4,817 | n/a |
IP0190 # 09 Y:2024 | 09 | 2024 | USE RADIANT HEATER FOR SPOT HEATING | $1,750 | $1,800 | n/a |
IP7021 # 01 Y:2024 | 01 | 2024 | INSTALL OCCUPANCY SENSORS | $16,580 | $50 | n/a |
IP7021 # 02 Y:2024 | 02 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $47 | $86 | n/a |
IP7021 # 03 Y:2024 | 03 | 2024 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $22,786 | $69,760 | n/a |