Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,140
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0157 # 03 Y:1999 | 03 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $2,437 | $875 | Not Implemented |
OK0568 # 01 Y:1999 | 01 | 1999 | INSTALL OCCUPANCY SENSORS | $233 | $731 | Not Implemented |
HO0194 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,344 | $27,758 | Not Implemented |
HO0194 # 04 Y:1999 | 04 | 1999 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $4,698 | $18,360 | Not Implemented |
HO0194 # 05 Y:1999 | 05 | 1999 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $460 | $300 | Not Implemented |
ND0317 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,051 | $1,500 | Not Implemented |
ND0317 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,579 | $7,583 | Not Implemented |
ND0317 # 03 Y:1999 | 03 | 1999 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $273 | $60 | Implemented |
ND0317 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $826 | $1,200 | Not Implemented |
ND0317 # 05 Y:1999 | 05 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,479 | $7,733 | Implemented |
ND0317 # 06 Y:1999 | 06 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,285 | $260 | Implemented |
MO0249 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,335 | $3,538 | Implemented |
MS0128 # 02 Y:1999 | 02 | 1999 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,291 | $149 | Implemented |
MS0128 # 03 Y:1999 | 03 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $905 | $472 | Implemented |
DS0128 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,686 | $60,411 | Implemented |
DS0129 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,030 | $6,676 | Not Implemented |
SD0213 # 01 Y:1999 | 01 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,397 | $1,830 | Implemented |
SF0159 # 08 Y:1999 | 08 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,589 | $21,750 | Implemented |
SF0159 # 09 Y:1999 | 09 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,339 | $1,339 | Implemented |
WI0336 # 05 Y:1999 | 05 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,244 | $6,000 | Not Implemented |
WI0336 # 08 Y:1999 | 08 | 1999 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $2,805 | $8,400 | Not Implemented |
UM0133 # 02 Y:1999 | 02 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $35,000 | $43,000 | Implemented |
WI0339 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $1,826 | $2,400 | Not Implemented |
WI0339 # 07 Y:1999 | 07 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $826 | $2,600 | Not Implemented |
WI0339 # 08 Y:1999 | 08 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $439 | $0 | Not Implemented |