Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,418
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0100 # 01 Y:2013 | 01 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $6,757 | $1,062 | Implemented |
UA0100 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,852 | $11,493 | Not Implemented |
TT0106 # 03 Y:2013 | 03 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,763 | $5,520 | Not Implemented |
TT0106 # 04 Y:2013 | 04 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,586 | $9,280 | Not Implemented |
UD0879 # 08 Y:2013 | 08 | 2013 | REDUCE VENTILATION AIR | $7,088 | $900 | Implemented |
UD0879 # 09 Y:2013 | 09 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,068 | $2,074 | Not Implemented |
OR0602 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $5,434 | $10,283 | Implemented |
SU0342 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $209 | $92 | Not Implemented |
OK0853 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $26,647 | $7,150 | Not Implemented |
OK0853 # 02 Y:2013 | 02 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,649 | $4,550 | Not Implemented |
OK0853 # 03 Y:2013 | 03 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,083 | $15,925 | Not Implemented |
OK0853 # 04 Y:2013 | 04 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $4,173 | $240 | Implemented |
OK0853 # 05 Y:2013 | 05 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $6,694 | $16,250 | Not Implemented |
OK0853 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $763 | $5,865 | Not Implemented |
OK0853 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,264 | $12,032 | Not Implemented |
AM0637 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,130 | $5,300 | Not Implemented |
AM0637 # 03 Y:2013 | 03 | 2013 | INSTALL SKYLIGHTS | $4,110 | $6,350 | Not Implemented |
AM0637 # 04 Y:2013 | 04 | 2013 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,790 | $4,250 | Not Implemented |
AM0637 # 08 Y:2013 | 08 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $260 | $0 | Not Implemented |
SF0431 # 01 Y:2013 | 01 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,402 | $0 | Not Implemented |
SF0431 # 05 Y:2013 | 05 | 2013 | ADD AREA LIGHTING SWITCHES | $10,130 | $19,788 | Implemented |
SF0431 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,348 | $83,669 | Implemented |
SF0431 # 07 Y:2013 | 07 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,616 | $9,150 | Not Implemented |
UA0097 # 01 Y:2013 | 01 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $11,720 | $2,301 | Not Implemented |
UA0097 # 02 Y:2013 | 02 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $10,770 | $3,452 | Not Implemented |