Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

10,035

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0452 # 06 Y:1991 06 1991 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $2,862 $2,400 Not Implemented
CO0230 # 06 Y:1991 06 1991 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $2,240 $10,970 Implemented
IA0014 # 04 Y:1991 04 1991 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $5,788 $6,475 Not Implemented
WI0135 # 07 Y:1991 07 1991 INSTALL TIMERS AND/OR THERMOSTATS $321 $400 Implemented
OK0361 # 03 Y:1991 03 1991 INSTALL TIMERS AND/OR THERMOSTATS $3,012 $1,050 Not Implemented
WI0135 # 03 Y:1991 03 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,489 $0 Implemented
CO0230 # 02 Y:1991 02 1991 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,070 $2,100 Implemented
AS0043 # 01 Y:1991 01 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $49,398 $0 Implemented
AS0044 # 01 Y:1991 01 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $23,526 $0 Implemented
AS0045 # 01 Y:1991 01 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $5,635 $0 Implemented
MA0230 # 06 Y:1991 06 1991 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,264 $0 Not Implemented
WI0135 # 05 Y:1991 05 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $399 $1,400 Implemented
IA0013 # 03 Y:1991 03 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,589 $600 Not Implemented
GT0455 # 04 Y:1991 04 1991 AIR CONDITION ONLY SPACE NECESSARY $1,540 $930 Not Implemented
KU0356 # 04 Y:1991 04 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $9,225 $34,500 Not Implemented
MA0225 # 02 Y:1991 02 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $5,481 $11,200 Not Implemented
SD0010 # 09 Y:1991 09 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $10,188 $18,000 Not Implemented
WI0131 # 11 Y:1991 11 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $499 $700 Not Implemented
WI0132 # 05 Y:1991 05 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $351 $500 Not Implemented
WI0133 # 06 Y:1991 06 1991 INSTALL TIMERS AND/OR THERMOSTATS $429 $200 Implemented
TN0442 # 02 Y:1991 02 1991 INSTALL TIMERS AND/OR THERMOSTATS $4,589 $1,330 Implemented
MA0226 # 02 Y:1991 02 1991 INSTALL TIMERS AND/OR THERMOSTATS $6,376 $0 Implemented
CO0228 # 07 Y:1991 07 1991 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $8,524 $16,400 Implemented
KU0354 # 01 Y:1991 01 1991 INSTALL TIMERS AND/OR THERMOSTATS $7,348 $1,000 Implemented
GT0449 # 07 Y:1991 07 1991 INSTALL TIMERS AND/OR THERMOSTATS $560 $600 Implemented