Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
221
matching recommendationsARC | 2.72 | SPACE CONDITIONING |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0958 # 08 Y:2016 | 08 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $2,283 | $4,147 | Not Implemented |
DL0171 # 07 Y:2016 | 07 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,885 | $0 | Implemented |
DL0171 # 03 Y:2016 | 03 | 2016 | LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION | $374 | $0 | Implemented |
TT0182 # 09 Y:2016 | 09 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $1,612 | $500 | Implemented |
MZ0218 # 05 Y:2016 | 05 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,810 | $0 | Not Implemented |
MZ0218 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,078 | $12,500 | Not Implemented |
MZ0217 # 02 Y:2016 | 02 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $27,674 | $30,000 | Not Implemented |
UK1611 # 05 Y:2016 | 05 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,216 | $1,200 | Implemented |
OK0951 # 06 Y:2016 | 06 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,980 | $7,000 | Not Implemented |
OK0951 # 05 Y:2016 | 05 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,675 | $2,816 | Implemented |
BD0493 # 01 Y:2016 | 01 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $17,520 | $1,900 | n/a |
AM0721 # 03 Y:2016 | 03 | 2016 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $4,710 | $360 | Not Implemented |
IP0076 # 01 Y:2016 | 01 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $13,525 | $18 | Implemented |
IA0568 # 01 Y:2016 | 01 | 2016 | REVISE SMOKE CLEANUP FROM OPERATIONS | $32,058 | $60,740 | Implemented |
OK0959 # 03 Y:2016 | 03 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $28,465 | $350 | Not Implemented |
IP0075 # 01 Y:2016 | 01 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $2,060 | $475 | Not Implemented |
SU0428 # 03 Y:2016 | 03 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $166 | $0 | Implemented |
UK1610 # 08 Y:2016 | 08 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,083 | $500 | Implemented |
BS0090 # 07 Y:2016 | 07 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $30 | $15 | Not Implemented |
OK0955 # 02 Y:2016 | 02 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,478 | $10,800 | Implemented |
OK0955 # 03 Y:2016 | 03 | 2016 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $598 | $220 | Implemented |
IP0074 # 04 Y:2016 | 04 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $13,398 | $951 | Implemented |
WM0096 # 06 Y:2016 | 06 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $869 | $1,230 | Not Implemented |
MA0763 # 07 Y:2016 | 07 | 2016 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $940 | $3,880 | Not Implemented |
LE0425 # 03 Y:2016 | 03 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $1,026 | $370 | Implemented |