Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

162

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0040 # 06 Y:2009 06 2009 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $39,750 $0 Implemented
IA0444 # 06 Y:2009 06 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $8,087 $6,000 Not Implemented
MI0180 # 02 Y:2009 02 2009 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $51,365 $2,000 Implemented
LL0316 # 05 Y:2009 05 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $585 $396 Not Implemented
MZ0039 # 01 Y:2009 01 2009 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $48,883 $510,446 Implemented
UD0803 # 03 Y:2009 03 2009 INSTALL HEAT PIPES / RAISE COOLING SETPOINT $17,615 $84,000 Not Implemented
UD0803 # 11 Y:2009 11 2009 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,432 $0 Not Implemented
UD0803 # 08 Y:2009 08 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $5,627 $0 Not Implemented
UD0803 # 01 Y:2009 01 2009 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $393,528 $8,000 Implemented
LE0291 # 06 Y:2009 06 2009 INSTALL TIMERS AND/OR THERMOSTATS $2,837 $125 Not Implemented
CO0624 # 05 Y:2009 05 2009 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $510 $5,340 Not Implemented
DL0040 # 06 Y:2009 06 2009 INSTALL TIMERS AND/OR THERMOSTATS $4,313 $2,804 Not Implemented
WV0393 # 02 Y:2009 02 2009 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $45,591 $127,000 Not Implemented
UM0355 # 03 Y:2009 03 2009 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,372 $500 Not Implemented
MA0652 # 04 Y:2009 04 2009 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $3,585 $6,600 Not Implemented
SD0416 # 05 Y:2009 05 2009 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $655 $0 Implemented
UF0426 # 06 Y:2009 06 2009 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $50,000 $25,000 Not Implemented
LL0315 # 04 Y:2009 04 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $235 $495 Not Implemented
UF0426 # 01 Y:2009 01 2009 CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS $20,276 $4,000 Not Implemented
UF0426 # 07 Y:2009 07 2009 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,382 $2,382 Not Implemented
LL0315 # 02 Y:2009 02 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,718 $300 Implemented
UM0354 # 04 Y:2009 04 2009 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $12,144 $4,200 Implemented
UD0802 # 03 Y:2009 03 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,645 $0 Implemented
SF0377 # 03 Y:2009 03 2009 USE RADIANT HEATER FOR SPOT HEATING $1,094 $2,088 Not Implemented
SF0377 # 08 Y:2009 08 2009 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,116 $25,320 Not Implemented