Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
328
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
RU0162 # 06 Y:1992 | 06 | 1992 | USE RADIANT HEATER FOR SPOT HEATING | $8,910 | $10,500 | Implemented |
RU0161 # 06 Y:1992 | 06 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,472 | $2,500 | Implemented |
RU0162 # 04 Y:1992 | 04 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $477 | $1,080 | Implemented |
RU0165 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $617 | $0 | Implemented |
RU0162 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $104 | $24 | Implemented |
RU0162 # 01 Y:1992 | 01 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $90 | $750 | Implemented |
RU0160 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,367 | $507 | Implemented |
RU0164 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $955 | $0 | Implemented |
RU0163 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,852 | $0 | Implemented |
RU0160 # 01 Y:1992 | 01 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,237 | $12,750 | Implemented |
RU0160 # 02 Y:1992 | 02 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $707 | $322 | Implemented |
RU0165 # 07 Y:1992 | 07 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,212 | $2,500 | Implemented |
RU0160 # 04 Y:1992 | 04 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,501 | $849 | Implemented |
RU0161 # 05 Y:1992 | 05 | 1992 | INSTALL / REPAIR INSULATION ON STEAM LINES | $157 | $60 | Implemented |
RU0161 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,075 | $183 | Implemented |
RU0160 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $678 | $0 | Implemented |
RU0164 # 06 Y:1992 | 06 | 1992 | OPTIMIZE PLANT POWER FACTOR | $2,580 | $2,500 | Implemented |
RU0161 # 01 Y:1992 | 01 | 1992 | INSTALL SET-BACK TIMERS | $689 | $100 | Implemented |
RU0160 # 07 Y:1992 | 07 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $9,901 | $11,500 | Implemented |
RU0160 # 03 Y:1992 | 03 | 1992 | COVER OPEN TANKS | $1,112 | $350 | Implemented |
RU0153 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $865 | $199 | Implemented |
RU0154 # 02 Y:1992 | 02 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,622 | $0 | Implemented |
RU0154 # 05 Y:1992 | 05 | 1992 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,001 | $300 | Implemented |
RU0154 # 03 Y:1992 | 03 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,405 | $2,500 | Implemented |
RU0156 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,848 | $0 | Implemented |