Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0242 # 03 Y:2002 | 03 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,518 | $1,217 | Implemented |
SF0242 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,176 | $572 | Implemented |
SF0241 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,590 | $0 | Implemented |
SF0240 # 06 Y:2002 | 06 | 2002 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $65,251 | $89,870 | Implemented |
SF0240 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,486 | $0 | Implemented |
SF0237 # 09 Y:2002 | 09 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $3,489 | $0 | Implemented |
SF0237 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,405 | $58,318 | Implemented |
SF0237 # 05 Y:2002 | 05 | 2002 | INSULATE BARE EQUIPMENT | $8,315 | $6,667 | Implemented |
SF0237 # 04 Y:2002 | 04 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,539 | $1,024 | Implemented |
SF0237 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,874 | $0 | Implemented |
SF0237 # 01 Y:2002 | 01 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $7,124 | $0 | Implemented |
SF0236 # 05 Y:2002 | 05 | 2002 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,418 | $5,500 | Implemented |
SF0236 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,279 | $0 | Implemented |
SF0236 # 02 Y:2002 | 02 | 2002 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $3,632 | $440 | Implemented |
SF0236 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,490 | $1,146 | Implemented |
SF0235 # 14 Y:2002 | 14 | 2002 | OPTIMIZE PLANT POWER FACTOR | $4,195 | $7,970 | Implemented |
SF0235 # 05 Y:2002 | 05 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,228 | $2,805 | Implemented |
SF0235 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,612 | $3,553 | Implemented |
SF0235 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,373 | $300 | Implemented |
SF0234 # 08 Y:2002 | 08 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $15,441 | $49,000 | Implemented |
SF0234 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,185 | $300 | Implemented |
SF0233 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,975 | $0 | Implemented |
SF0228 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,326 | $23,370 | Implemented |
SF0228 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,476 | $6,382 | Implemented |
SF0230 # 02 Y:2002 | 02 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $537 | $474 | Implemented |