Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

829

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0499 # 05 Y:2005 05 2005 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,285 $300 Implemented
WI0499 # 06 Y:2005 06 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $967 $1,280 Implemented
WI0499 # 07 Y:2005 07 2005 INSTALL SPECTRAL REFLECTORS / DELAMP $344 $0 Implemented
WI0497 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33,445 $86,400 Implemented
WI0497 # 04 Y:2005 04 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $12,421 $0 Implemented
WI0497 # 05 Y:2005 05 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $4,656 $500 Implemented
WI0497 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,470 $60 Implemented
WI0496 # 01 Y:2005 01 2005 $21,656 $6,750 Implemented
WI0496 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,914 $57,240 Implemented
WI0496 # 03 Y:2005 03 2005 INSTALL TIMERS AND/OR THERMOSTATS $4,904 $0 Implemented
WI0495 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,256 $32,760 Implemented
WI0495 # 03 Y:2005 03 2005 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,320 $360 Implemented
WI0495 # 05 Y:2005 05 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,165 $0 Implemented
WI0495 # 07 Y:2005 07 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $1,135 $1,500 Implemented
WI0495 # 09 Y:2005 09 2005 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $242 $200 Implemented
WI0494 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,231 $12,960 Implemented
WI0492 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,385 $25,200 Implemented
WI0492 # 04 Y:2005 04 2005 $5,832 $1,000 Implemented
WI0492 # 05 Y:2005 05 2005 IMPROVE LUBRICATION PRACTICES $3,033 $2,155 Implemented
WI0492 # 07 Y:2005 07 2005 INSTALL TIMERS AND/OR THERMOSTATS $1,494 $600 Implemented
WI0492 # 08 Y:2005 08 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,335 $1,280 Implemented
WI0491 # 03 Y:2005 03 2005 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $7,911 $5,000 Implemented
WI0491 # 05 Y:2005 05 2005 INSTALL OCCUPANCY SENSORS $1,112 $1,680 Implemented
WI0491 # 06 Y:2005 06 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $706 $1,244 Implemented
WI0490 # 03 Y:2005 03 2005 $7,000 $1,000 Implemented