Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,628
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0619 # 02 Y:2001 | 02 | 2001 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $18,573 | $6,262 | Implemented |
UD0619 # 03 Y:2001 | 03 | 2001 | METER WASTE WATER | $14,438 | $500 | Implemented |
UD0619 # 05 Y:2001 | 05 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,322 | $940 | Implemented |
UD0619 # 06 Y:2001 | 06 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,846 | $5,628 | Implemented |
UD0619 # 07 Y:2001 | 07 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,873 | $2,400 | Implemented |
UM0185 # 01 Y:2001 | 01 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,400 | $600 | Implemented |
UM0185 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,546 | $450 | Implemented |
UM0185 # 05 Y:2001 | 05 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $50,525 | $10,000 | Implemented |
UD0618 # 04 Y:2001 | 04 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,474 | $6,280 | Implemented |
UD0618 # 05 Y:2001 | 05 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,038 | $1,450 | Implemented |
UD0617 # 01 Y:2001 | 01 | 2001 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $90,000 | $111,000 | Implemented |
UD0617 # 02 Y:2001 | 02 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $98,016 | $60,000 | Implemented |
UD0617 # 05 Y:2001 | 05 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,578 | $695 | Implemented |
UD0615 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,423 | $42,285 | Implemented |
UD0615 # 02 Y:2001 | 02 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $17,160 | $0 | Implemented |
UD0615 # 06 Y:2001 | 06 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,831 | $8,500 | Implemented |
UD0613 # 02 Y:2001 | 02 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $15,606 | $14,000 | Implemented |
UD0613 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,566 | $0 | Implemented |
UD0613 # 04 Y:2001 | 04 | 2001 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $5,513 | $5,000 | Implemented |
UD0613 # 05 Y:2001 | 05 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,342 | $0 | Implemented |
UD0614 # 02 Y:2001 | 02 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $53,184 | $30,570 | Implemented |
UD0614 # 05 Y:2001 | 05 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,252 | $0 | Implemented |
UD0612 # 01 Y:2001 | 01 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,331 | $200 | Implemented |
UD0612 # 03 Y:2001 | 03 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $782 | $800 | Implemented |
UD0612 # 05 Y:2001 | 05 | 2001 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $533 | $1,200 | Implemented |