Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,405
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0054 # 05 Y:2014 | 05 | 2014 | USE SOLAR HEAT TO MAKE ELECTRICTY | $934 | $0 | Implemented |
WM0054 # 07 Y:2014 | 07 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $232 | $720 | Implemented |
WM0053 # 02 Y:2014 | 02 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $17,731 | $1,292 | Implemented |
WM0053 # 10 Y:2014 | 10 | 2014 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,892 | $0 | Implemented |
WM0053 # 12 Y:2014 | 12 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,677 | $19,918 | Implemented |
WM0053 # 13 Y:2014 | 13 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $560 | $512 | Implemented |
WM0052 # 04 Y:2014 | 04 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,464 | $602 | Implemented |
WM0052 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $391 | $375 | Implemented |
WM0051 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,648 | $27,260 | Implemented |
WM0051 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,050 | $225 | Implemented |
WM0051 # 09 Y:2014 | 09 | 2014 | REPLACE BOILER | $11,306 | $16,000 | Implemented |
IA0520 # 01 Y:2014 | 01 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,603 | $2,179 | Implemented |
IA0520 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,486 | $234 | Implemented |
IA0520 # 06 Y:2014 | 06 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $429 | $253 | Implemented |
IA0520 # 08 Y:2014 | 08 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $290 | $392 | Implemented |
WM0049 # 02 Y:2014 | 02 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,079 | $0 | Implemented |
WM0049 # 04 Y:2014 | 04 | 2014 | USE POWER DURING OFF-PEAK PERIODS | $1,567 | $0 | Implemented |
WM0049 # 09 Y:2014 | 09 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $13,969 | $41,765 | Implemented |
WM0049 # 10 Y:2014 | 10 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,788 | $1,290 | Implemented |
WM0049 # 11 Y:2014 | 11 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,253 | $3,096 | Implemented |
WM0048 # 01 Y:2014 | 01 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,124 | $239 | Implemented |
WM0048 # 02 Y:2014 | 02 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $18,624 | $53,646 | Implemented |
WM0048 # 03 Y:2014 | 03 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $2,471 | $270 | Implemented |
WM0048 # 05 Y:2014 | 05 | 2014 | OPTIMIZE PLANT POWER FACTOR | $5,162 | $24,038 | Implemented |
WM0047 # 01 Y:2014 | 01 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $19,205 | $13,000 | Implemented |