IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,629

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0145 # 06 Y:1999 06 1999 USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS $24,222 $60,000 Implemented
UM0145 # 07 Y:1999 07 1999 IMPROVE SPACE COMFORT CONDITIONING $16,869 $14,495 Implemented
UM0144 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,661 $110 Implemented
UM0144 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $647 $1,000 Implemented
UM0144 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,285 $350 Implemented
UM0144 # 06 Y:1999 06 1999 REDUCE SCRAP PRODUCTION $29,091 $5,000 Implemented
UM0144 # 07 Y:1999 07 1999 INSTALL SYSTEM TO COLLECT SCRAP $7,680 $584 Implemented
UM0143 # 03 Y:1999 03 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $198 $500 Implemented
UM0143 # 06 Y:1999 06 1999 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $5,909 $3,434 Implemented
UM0142 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $416 $450 Implemented
UM0142 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,691 $1,250 Implemented
UM0142 # 03 Y:1999 03 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $39 $0 Implemented
UM0142 # 06 Y:1999 06 1999 OPTIMIZE PLANT POWER FACTOR $7,489 $10,860 Implemented
UM0142 # 07 Y:1999 07 1999 METER WASTE WATER $6,412 $500 Implemented
ND0321 # 01 Y:1999 01 1999 PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW $103,932 $0 Implemented
ND0321 # 04 Y:1999 04 1999 UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID $1,555 $7,050 Implemented
ND0321 # 05 Y:1999 05 1999 OPTIMIZE PLANT POWER FACTOR $2,989 $12,575 Implemented
ND0321 # 08 Y:1999 08 1999 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $730 $125 Implemented
ND0321 # 10 Y:1999 10 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $158 $130 Implemented
ND0322 # 02 Y:1999 02 1999 USE OPTIMUM TEMPERATURE $161 $0 Implemented
UM0141 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,742 $910 Implemented
UM0141 # 04 Y:1999 04 1999 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,664 $3,750 Implemented
UM0141 # 05 Y:1999 05 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $7,277 $0 Implemented
UM0141 # 06 Y:1999 06 1999 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $126,000 $50,000 Implemented
UM0139 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,007 $450 Implemented