Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,668
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0320 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $131 | $0 | Implemented |
ND0320 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $695 | $1,893 | Implemented |
ND0320 # 03 Y:1999 | 03 | 1999 | USE PHOTOCELL CONTROLS | $303 | $600 | Implemented |
ND0320 # 04 Y:1999 | 04 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $737 | $255 | Implemented |
ND0320 # 05 Y:1999 | 05 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $320 | $80 | Implemented |
ND0320 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $451 | $455 | Implemented |
UM0137 # 01 Y:1999 | 01 | 1999 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $420 | $0 | Implemented |
UM0137 # 02 Y:1999 | 02 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,358 | $40,000 | Implemented |
UM0137 # 03 Y:1999 | 03 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $4,047 | $16,100 | Implemented |
UM0136 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,707 | $9,821 | Implemented |
UM0136 # 02 Y:1999 | 02 | 1999 | AIR CONDITION ONLY SPACE NECESSARY | $1,684 | $400 | Implemented |
UM0135 # 01 Y:1999 | 01 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,898 | $20,000 | Implemented |
UM0135 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,690 | $50 | Implemented |
UM0135 # 04 Y:1999 | 04 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,660 | $2,500 | Implemented |
UM0135 # 05 Y:1999 | 05 | 1999 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $986 | $1,500 | Implemented |
UM0135 # 06 Y:1999 | 06 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $735 | $100 | Implemented |
UM0133 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,000 | $2,000 | Implemented |
UM0133 # 02 Y:1999 | 02 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $35,000 | $43,000 | Implemented |
UM0133 # 03 Y:1999 | 03 | 1999 | MINIMIZE WATER USAGE | $35,600 | $5,500 | Implemented |
UM0133 # 04 Y:1999 | 04 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $21,232 | $14,700 | Implemented |
UM0133 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $259,748 | $13,300 | Implemented |
UM0130 # 02 Y:1999 | 02 | 1999 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,970 | $0 | Implemented |
UM0130 # 04 Y:1999 | 04 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $11,820 | $0 | Implemented |
ND0318 # 11 Y:1999 | 11 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $280 | $180 | Implemented |
ND0309 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,616 | $17,376 | Implemented |