Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
675
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0592 # 03 Y:2012 | 03 | 2012 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $40,400 | $70,000 | Implemented |
OR0592 # 04 Y:2012 | 04 | 2012 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $15,020 | $0 | Implemented |
OR0588 # 01 Y:2012 | 01 | 2012 | IMPROVE HANDLING PRACTICES | $7,884 | $60 | Implemented |
OR0588 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,053 | $8,053 | Implemented |
OR0588 # 05 Y:2012 | 05 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $17,738 | $17,500 | Implemented |
OR0587 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $2,854 | $2,854 | Implemented |
OR0586 # 01 Y:2012 | 01 | 2012 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $7,216 | $7,500 | Implemented |
OR0586 # 02 Y:2012 | 02 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,374 | $200 | Implemented |
OR0586 # 03 Y:2012 | 03 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,914 | $812 | Implemented |
OR0586 # 06 Y:2012 | 06 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $666 | $500 | Implemented |
OR0586 # 07 Y:2012 | 07 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $762 | $0 | Implemented |
OR0586 # 08 Y:2012 | 08 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,517 | $3,375 | Implemented |
OR0579 # 01 Y:2012 | 01 | 2012 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $15,066 | $0 | Implemented |
OR0579 # 03 Y:2012 | 03 | 2012 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $23,346 | $55,000 | Implemented |
OR0579 # 07 Y:2012 | 07 | 2012 | USE PHOTOCELL CONTROLS | $17,340 | $46,680 | Implemented |
UW0053 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,936 | $1,900 | Implemented |
UW0053 # 02 Y:2011 | 02 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $13,673 | $11,000 | Implemented |
UW0053 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,663 | $160,551 | Implemented |
UW0051 # 04 Y:2011 | 04 | 2011 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $4,139 | $2,295 | Implemented |
UW0051 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,680 | $10,004 | Implemented |
UW0050 # 01 Y:2011 | 01 | 2011 | PAY BILLS ON TIME TO AVOID LATE FEES | $0 | $0 | Implemented |
UW0049 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,756 | $1,300 | Implemented |
UW0049 # 02 Y:2011 | 02 | 2011 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $9,443 | $7,200 | Implemented |
UW0045 # 04 Y:2011 | 04 | 2011 | INSULATE BARE EQUIPMENT | $5,260 | $220 | Implemented |
UW0045 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,963 | $1,930 | Implemented |