Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

60

matching recommendations
Reset
SIC 306 Fabricated Rubber Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0075 # 04 Y:2004 04 2004 $156,419 $6,500 Implemented
LM0075 # 06 Y:2004 06 2004 INSULATE BARE EQUIPMENT $309 $101 Implemented
SD0333 # 08 Y:2004 08 2004 INCREASE USE OF AUTOMATION $57,000 $110,000 Implemented
SD0333 # 05 Y:2004 05 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,128 $0 Implemented
SD0333 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,253 $192 Implemented
SD0333 # 02 Y:2004 02 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $14,470 $600 Implemented
SD0324 # 04 Y:2003 04 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $7,504 $70 Implemented
SD0319 # 16 Y:2003 16 2003 REDUCE SCRAP PRODUCTION $222,070 $9,000 Implemented
SD0319 # 19 Y:2003 19 2003 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,166 $0 Implemented
SD0319 # 05 Y:2003 05 2003 REPAIR OR REPLACE STEAM TRAPS $22,467 $9,950 Implemented
SD0319 # 15 Y:2003 15 2003 CLOSE OFF UNNEEDED STEAM LINES $2,248 $1,350 Implemented
SD0319 # 13 Y:2003 13 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $3,005 $1,500 Implemented
SD0319 # 10 Y:2003 10 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $11,780 $1,550 Implemented
SF0245 # 03 Y:2002 03 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,576 $4,115 Implemented
SF0245 # 04 Y:2002 04 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $8,585 $20,725 Implemented
SF0245 # 06 Y:2002 06 2002 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $2,738 $6,972 Implemented
SF0245 # 07 Y:2002 07 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,193 $0 Implemented
LM0019 # 05 Y:2001 05 2001 $10,000 $3,000 Implemented
LM0019 # 04 Y:2001 04 2001 $3,087 $450 Implemented
SD0246 # 08 Y:2000 08 2000 $32,080 $20,000 Implemented
SD0246 # 06 Y:2000 06 2000 $220,320 $13,000 Implemented
SD0246 # 05 Y:2000 05 2000 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $336 $0 Implemented
SD0246 # 03 Y:2000 03 2000 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $3,276 $3,000 Implemented
SD0234 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,069 $1,425 Implemented
SF0032 # 06 Y:1994 06 1994 INSULATE BARE EQUIPMENT $1,244 $4,261 Implemented