Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
212
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0307 # 06 Y:2006 | 06 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $14,621 | $1,500 | Implemented |
UM0307 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,428 | $2,000 | Implemented |
UM0307 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,814 | $10,054 | Implemented |
UM0307 # 10 Y:2006 | 10 | 2006 | INSULATE BARE EQUIPMENT | $3,606 | $1,191 | Implemented |
UM0307 # 12 Y:2006 | 12 | 2006 | INSULATE BARE EQUIPMENT | $3,085 | $0 | Implemented |
UM0307 # 13 Y:2006 | 13 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $754 | $75 | Implemented |
UM0277 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,247 | $1,000 | Implemented |
UM0277 # 02 Y:2005 | 02 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,442 | $1,000 | Implemented |
UM0277 # 01 Y:2005 | 01 | 2005 | REDUCE SCRAP PRODUCTION | $34,320 | $7,500 | Implemented |
UM0235 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,415 | $675 | Implemented |
UM0235 # 03 Y:2003 | 03 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,576 | $9,600 | Implemented |
UM0234 # 01 Y:2003 | 01 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $71,900 | $180,000 | Implemented |
UM0234 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,603 | $120,000 | Implemented |
UM0227 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,000 | $1,725 | Implemented |
UM0227 # 07 Y:2003 | 07 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,640 | $1,300 | Implemented |
UM0217 # 08 Y:2002 | 08 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $2,050 | $1,350 | Implemented |
UM0217 # 07 Y:2002 | 07 | 2002 | $2,860 | $2,500 | Implemented | |
UM0217 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $290 | $680 | Implemented |
UM0217 # 02 Y:2002 | 02 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $310 | $600 | Implemented |
UM0217 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $396 | $75 | Implemented |
UM0213 # 07 Y:2002 | 07 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,355 | $1,468 | Implemented |
UM0213 # 06 Y:2002 | 06 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,292 | $3,000 | Implemented |
UM0213 # 04 Y:2002 | 04 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,460 | $3,600 | Implemented |
UM0213 # 05 Y:2002 | 05 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $11,201 | $500 | Implemented |
UM0213 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,927 | $71,714 | Implemented |