Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
90
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0177 # 06 Y:2016 | 06 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,002 | $1,400 | Implemented |
TT0159 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $31,644 | $3,000 | Implemented |
TT0159 # 07 Y:2015 | 07 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $2,995 | $1,070 | Implemented |
TT0159 # 08 Y:2015 | 08 | 2015 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,187 | $500 | Implemented |
TT0142 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,651 | $3,000 | Implemented |
TT0142 # 01 Y:2014 | 01 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,305 | $1,400 | Implemented |
TT0142 # 06 Y:2014 | 06 | 2014 | USE PHOTOCELL CONTROLS | $49 | $45 | Implemented |
TT0095 # 07 Y:2012 | 07 | 2012 | INSTALL OCCUPANCY SENSORS | $39,751 | $33,080 | Implemented |
TT0095 # 04 Y:2012 | 04 | 2012 | INSULATE BARE EQUIPMENT | $1,770 | $1,195 | Implemented |
TT0095 # 01 Y:2012 | 01 | 2012 | REPLACE BOILER | $8,685 | $5,000 | Implemented |
TT0095 # 05 Y:2012 | 05 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,668 | $7,000 | Implemented |
TT0029 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,600 | $12,000 | Implemented |
TT0029 # 02 Y:2008 | 02 | 2008 | INSULATE BARE EQUIPMENT | $52,700 | $1,000 | Implemented |
TT0029 # 07 Y:2008 | 07 | 2008 | OPTIMIZE PLANT POWER FACTOR | $4,855 | $13,300 | Implemented |
TT0005 # 05 Y:2007 | 05 | 2007 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,002 | $200 | Implemented |
TT0005 # 06 Y:2007 | 06 | 2007 | OPTIMIZE PLANT POWER FACTOR | $62,060 | $50,000 | Implemented |
TT0005 # 02 Y:2007 | 02 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,570 | $4,816 | Implemented |
TT0005 # 08 Y:2007 | 08 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $47,304 | $2,000 | Implemented |
TN0681 # 02 Y:2000 | 02 | 2000 | $20,000 | $16,083 | Implemented | |
TN0681 # 01 Y:2000 | 01 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $32,683 | $83,500 | Implemented |
TN0681 # 03 Y:2000 | 03 | 2000 | $11,200 | $23,000 | Implemented | |
AR0164 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,915 | $1,521 | Implemented |
AR0164 # 01 Y:1999 | 01 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,789 | $2,617 | Implemented |
TN0661 # 06 Y:1999 | 06 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $25,103 | $30,600 | Implemented |
TN0661 # 01 Y:1999 | 01 | 1999 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $175,335 | $5,000 | Implemented |