Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
319
matching recommendationsSIC | 3462 | Iron And Steel Forgings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0347 # 05 Y:1999 | 05 | 1999 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,037 | $0 | Implemented |
WI0347 # 07 Y:1999 | 07 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $638 | $1,000 | Implemented |
SD0216 # 01 Y:1999 | 01 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,277 | $1,650 | Implemented |
SD0216 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,961 | $1,060 | Implemented |
SD0216 # 04 Y:1999 | 04 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $840 | $0 | Implemented |
OK0562 # 01 Y:1998 | 01 | 1998 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $14,801 | $1,936 | Implemented |
OK0562 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $850 | $110 | Implemented |
OK0562 # 05 Y:1998 | 05 | 1998 | INSTALL OCCUPANCY SENSORS | $360 | $532 | Implemented |
OK0562 # 07 Y:1998 | 07 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $7,200 | $288 | Implemented |
OK0562 # 08 Y:1998 | 08 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,160 | $0 | Implemented |
OK0562 # 09 Y:1998 | 09 | 1998 | METER WASTE WATER | $233 | $0 | Implemented |
TN0641 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,810 | $5,000 | Implemented |
TN0641 # 03 Y:1998 | 03 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $3,560 | $2,500 | Implemented |
TN0641 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,130 | $980 | Implemented |
AM0328 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $11,750 | $0 | Implemented |
AM0328 # 07 Y:1998 | 07 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $500 | $500 | Implemented |
UD0542 # 01 Y:1998 | 01 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $183,600 | $0 | Implemented |
UD0542 # 03 Y:1998 | 03 | 1998 | USE POWER DURING OFF-PEAK PERIODS | $11,143 | $0 | Implemented |
UD0542 # 04 Y:1998 | 04 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $8,400 | $0 | Implemented |
UD0542 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,513 | $14,128 | Implemented |
WI0318 # 01 Y:1998 | 01 | 1998 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $89,367 | $0 | Implemented |
WI0318 # 05 Y:1998 | 05 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $555 | $0 | Implemented |
WI0318 # 06 Y:1998 | 06 | 1998 | INSULATE BARE EQUIPMENT | $417 | $742 | Implemented |
WI0318 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $571 | Implemented |
AM0312 # 01 Y:1998 | 01 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $30,640 | $1,200 | Implemented |