Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
785
matching recommendationsSIC | 358 | Refrigeration And Service Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0001 # 07 Y:2001 | 07 | 2001 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $12,500 | $0 | Implemented |
TN0694 # 02 Y:2000 | 02 | 2000 | ADD AREA LIGHTING SWITCHES | $17,510 | $25,030 | Implemented |
TN0694 # 03 Y:2000 | 03 | 2000 | DEVELOP A REPAIR/REPLACE POLICY | $10,755 | $5,075 | Implemented |
TN0694 # 11 Y:2000 | 11 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,365 | $0 | Implemented |
IA0258 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,870 | $753 | Implemented |
IA0258 # 04 Y:2000 | 04 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $288 | $25 | Implemented |
IA0258 # 05 Y:2000 | 05 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,920 | $1,206 | Implemented |
MS0156 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,681 | $200 | Implemented |
MS0156 # 04 Y:2000 | 04 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $74,209 | $6,000 | Implemented |
AS0271 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $708 | $607 | Implemented |
AS0271 # 05 Y:2000 | 05 | 2000 | KEEP EQUIPMENT CLEAN | $3,601 | $232 | Implemented |
AS0271 # 06 Y:2000 | 06 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $795 | $120 | Implemented |
AS0271 # 08 Y:2000 | 08 | 2000 | APPLY FOR INVESTMENT INCENTIVES | $1,640 | $60 | Implemented |
AS0271 # 09 Y:2000 | 09 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $10,128 | $120 | Implemented |
NC0183 # 01 Y:2000 | 01 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,429 | $2,731 | Implemented |
NC0183 # 02 Y:2000 | 02 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,611 | $11,000 | Implemented |
NC0183 # 04 Y:2000 | 04 | 2000 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,091 | $3,300 | Implemented |
NC0183 # 05 Y:2000 | 05 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $884 | $600 | Implemented |
NC0183 # 08 Y:2000 | 08 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $6,838 | $3,700 | Implemented |
NC0183 # 10 Y:2000 | 10 | 2000 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $20,448 | $5,000 | Implemented |
MS0152 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,518 | $457 | Implemented |
MS0152 # 04 Y:2000 | 04 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $3,911 | $2,652 | Implemented |
WI0358 # 01 Y:1999 | 01 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $97,790 | $44,000 | Implemented |
WI0358 # 07 Y:1999 | 07 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $107 | Implemented |
CO0443 # 01 Y:1999 | 01 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,960 | $0 | Implemented |